Assemble the continuous-flow heater as shown in the
illustrations. Observe the information in the text.
Sa fe t y in for m a t ion
I
The continuous-flow heater must only be connected
and started up by an authorized technician.
The statutory regulations of the respective country, as well
I
as those of the local electricity and water suppliers must
be adhered to.
The continuous-flow heater is an appliance of protection
I
class I and must be connected to the protective earth
conductor.
The unit must be durably connected to permanently
I
installed lines.
I
In order to meet the current safety requirements, an
all-pole disconnecting device must be present on the
installation side. The contact gap must be at least 3 mm.
I
The continuous-flow heater is suitable for enclosed
(pressurized) operation only.
I
The tap fittings must be permitted for operation with
enclosed (pressurized) continuous-flow heaters.
The continuous-flow heater must only be connected to
I
a cold-water pipe.
I
The continuous-flow heater is suitable for connection to
DVGW-tested plastic pipes.
I
The continuous-flow heater must only be installed in
a frost-free room.
Prior to installation, the electric connecting cord
I
must be disconnected from the mains voltage and
the water supply cut off!
Only connect the electric supply after the water
I
supply.
When making holes in the rear wall, only make the
I
number of holes required for installation. If the appliance
is reinstalled, any holes that are not used must be made
watertight.
Live components must not be touched subsequent to
I
installation.
GB
A s s e m bly
I.
Unpacking/removing the
housing cover
I
Unpack the appliance and check for transportation
damage.
Dispose of the packaging and, where applicable, the old
I
appliance, in an environmentally conscious manner.
Preparation for assembly
II.
Wall-mounted assembly
III.
I
The continuous-flow heater must be fitted securely to the
wall. If required, secure the appliance using the lower
adjusting screws.
I
The distance from the wall is variable. This allows you to
compensate for any unevenness in the wall surface.
The sleeve must fit tightly round the connection cable. If
I
the sleeve is damaged during installation, the holes must
be sealed water-tight.

Water supply

IV.
The flow-through heater must be vented. Open the warm
I
water tap completely and allow to flow through for one
minute.

Electric supply

V.
I
The mains connection terminal can either be mounted
above or below. At least 40 mm of the connecting cord's
insulating jacket must be clamped inside the appliance.
Startup
VI.
I
At low water pipe pressure, check whether the II setting
switches on even when water is drawn from several cold-
water taps simultaneously. If not, remove the flow limiter
(refer to additional information A).
I
Instruct the user with regard to the operation of the
continuous-flow heater.
I
Separate the required language version from the rest of
the operating instructions. This can be kept in the swing-
out control panel of the continuous-flow heater.
A
B

Additional information

If the water pressure of the interior system is low, do not
I
operate the continuous-flow heater at full power, but
remove the flow limiter (Fig. A).
Priority circuit for the combined operation of electric
I
storage heaters (Fig. B).