13. Technical Data

EN
Height measurements
DE
FR
ES
IT
Distance Accuracy
PT
(Standard Deviation)
NL
Range
NO
SV
Optical - Shortest focusing
distance
FI
Measuring time single
DA
measure (Electronic)
Circular Bubble
Compensator
RS232 Port*
Phone Jab Port*
Technical Data
Standard deviation per km double run (ISO 17123-2):
• Electronic measurement with Sprinter aluminum barcode staff:
• 1.0 mm (Sprinter 250M)
• 1.5 mm (Sprinter 150/150M)
• Optical measurement with standard aluminum E-scale/Numeral staff: 2.5 mm
• Standard Deviation for single staff reading: 0.6 mm (electronic) and 1.2 mm (optical) at 30m
10 mm for D<= 10 m
Distance in m x 0.001 for D>10 m
Distance measuring range for electronic measurements with standard aluminum barcode staff: 2 m to
100 m.
50 cm
Typically 3 seconds and less in normal daylight condition; needs longer measuring time in uniform dim
light condition (20 lux).
Circular Bubble Sensitivity: 10'/2 mm
Magnet damped pendulum compensator with electronic range monitoring
• Tilt Warning Range (Electronically): ± 10'
• Compensator range (Mechanically): ± 10'
• Setting accuracy: 0.8" max. (Standard Deviation)
• Magnetic field sensitivity: < 10"
(Line-of-sight difference in horizontal constant magnetic field at a field strength of up 5 Gauss)
For RS232 cable connection to external battery and communication to PC / data collector.
For USB cable connection to communication to PC.