16
Valve seat
17
Exhalation membrane
18
Protective cap
Gasket
19
20
Filter holder
Filter
21
a
Particle filter
Gas filter
b
a
+
b
Combined filter
22
Pre-filter, SR221
Pre-filter holder
23
2.3 Filter
You can identify the filter type by the colour
code on the filter. See the User instructions
for filters. Note that a particle filter provides
protection only against particles and a gas
filter provides protection only against gases/
vapours. A combined filter protects against
both gases/vapours and particles.
Item
• Particle filter P3 R, SR 510
• Gas filter A1, SR 217
• Gas filter A2, SR 218
• Gas filter AX, SR 298
• Gas filter ABE1, SR 315
• Gas filter ABE2, SR 294
• Gas filter K1, SR 316
• Gas filter K2, SR 295
• Gas filter SR 297 ABEK1
• Combined filter
ABEK1-Hg-P3 R, SR 299-2
2.4 Accessories / Spare parts
Item
Membrane kit SR 369
24
Inhalation membrane 1x
Exhalation membranes 2x
Protective caps 2x
Service kit
25
Head harness
13
Membrane kit
23
Pre-filter holder
26
Protective hood SR 64
27
Protective hood SR 345
28
Protective hood SR 346
Storage box SR 230
29
Storage bag SR 339
30
Voice amplifier SR 324
31
Test adapter SR 328
32
26
-
-
-
R01-3004
R01-3005
-
H02-0312
R01-0605
Ordering. No.
H02-1312
H02-2512
H02-2112
H02-2412
H02-3212
H02-3312
H02-4212
H02-4312
H02-5312
H02-6512
Ordering. No.
R01-2004
14
-
16
-
17
-
R01-3005
-
-
-
22
H09-0301
H09-1012
H09-1112
H09-3012
H09-0112
T01-1217
T01-1202
Cleaning tissues SR 5226,
4
box of 50
5
ID-tag
Storage bag, 50x
7
Compressed air attachment
When the half mask is used with compressed
air attachment SR 307 the user instructions
for the relevant equipment must be followed.
3. Use
3.1 Installation
Select the appropriate protection. Remain in
a safe atmosphere and select the appropriate
filter.
Fasten ID-tag
See 2.1 Delivery check
Fit the filter in the mask
See 4.4.6 Fitting the filter in a mask
3.2 Visual check before use
Check the mask body, membranes, and
33
membrane seats. Replace if worn, broken,
or in other way defect.
• Check that you have selected the right filter.
See the User instructions for filters.
34
Check that the filter is fitted properly.
Check that the use-by date has not been
35
passed. The use-by date is valid provided
that the filter packaging is unopened.
• Check that the mask is complete, correctly
assembled and thoroughly cleaned.
3.3 Putting the mask on
• Remove any hood, glasses or ear protection
from head.
Put the mask on.
36 37 38
• Take out any twists or tangles.
Adjust the harness.
39
• Wiggle the respirator until it fits comfortably.
3.4 Fit check
• Put the mask on.
Place the palm of your hand lightly over the
40
hole on the pre-filter holder to make it tight.
• Take a deep breat and hold your breath for
about 10 s.
If the mask is tight, it will be pressed against
your face.
H09-0401
R09-0101
R01-0607
-
8
12
54
56
-