Commissioning

• E2: plug pin 12 pole (M23)
Assignment output circuit OP, LD
Signal
/B
+SUB (Sense line)
0
/0
A
/A
B
GND
SGND (Sense line)
+UB
nc
Shielding on connector housing
5 Commissioning
Please carefully read the information on the encoder's mechanical and
electrical connection. This will ensure a trouble free commissioning and
operation.
Before operation, please check again:
• that the supply voltage's polarity is correct.
• correct connection of cable and signal lines.
• secure encoder fixation.
The encoder's operating voltage must be switched on together with the
downstream electronic unit (e. g., control) to avoid latch-up effects on the
outputs of the encoder.
` Now the encoder can be used.
IV5800 · Date 14.03.2018 · Art. No. 89310 · Mod. status 102/18
Pin
1
2
3
4
5
6
8
10
11
12
7, 9
English
21
10 9 12
1
8
2
7
3
6
4
5
11
viewing side =
plug-in side-
plug pin