4.3
Output
Output signal
Current
Step response T
90
Burden
4 to 20 mA, two-wire
Burden influence
4.4
Mechanical features
Material
Process connection
Membrane
Case
Electrical connection
Weight
Explosion protection
4.5
Environmental influences
Ambient temperature
Medium temperature
Storage temperature
Protection type
Electromagnetic compatibility
Interference emission
Interference immunity
Mechanical load
c
Shock resistance
d
Vibration resistance
a
EN 61326
b
The product is suitable for industrial use as well as for households and small businesses.
c
DIN EN 60068-2-27
d
DIN EN 60068-2-6
4 to 20 mA, 2-wire
≤ 2 ms
R
≤ (U
-16 V) ÷ 0.022 A (Ω)
B
B
≤ 0.004 % per 100 Ω
316 Ti
Exception: 316 L (process connection 999: to customer specifications)
316 L
304
PA, nickel-plated zinc diecast (electrical connection 36: round plug M12 × 1)
Silicone (electrical connection 11: attached cable),
PUR (electrical connection 99: special version)
170 g (pressure transmitter with process connection 504: G 1/2)
II 2G Ex ib IIC T6 ... T4 Gb
II 2D Ex ib IIIC T70°C ... T100°C Db
Equipment Protection Level Gb temperature class
T4: -40 to +85 °C
T5: -40 to +70 °C
T6: -40 to +55 °C
Equipment Protection Level Db maximum surface temperature
T100 °C: -40 to +85 °C
T85 °C: -40 to +70 °C
T70 °C: -40 to +55 °C
-40 to +85 °C
-40 to +100 °C
IP65 acc. to DIN EN 60529
a
b
Class B
Industrial requirement
100 g/1 ms
20 g at 15 to 2000 Hz
4 Technical data
13