Herunterladen Inhalt Inhalt Diese Seite drucken

Replacing The Cassette Seal; Replacing The Bayonet Seal - Dometic CT 4050/4110 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

CT4000
8.3

Replacing the cassette seal

➤ Release the slider from the cassette (chapter "Releasing the slider from the
cassette" on page 27).
➤ Push back the cover so that the seal is accessible (fig. g, page 10).
➤ Remove the support ring and the seal (fig. g, page 10).
A
NOTICE!
The seal must be positioned uniformly in the opening (fig. h, page 10)
so that the cassette is sealed and the slider can move easily.
➤ Insert the new seal (fig. i, page 11).
➤ Insert the support ring (fig. j, page 11).
➤ Grease all areas.
!
CAUTION! Danger of crushing!
Do not reach into the opening when you close the cover.
➤ Close the cover (fig. k, page 11).
➤ Place the slider back on.
8.4

Replacing the bayonet seal

➤ Release the slider from the cassette (chapter "Releasing the slider from the
cassette" on page 27).
➤ Remove the old seal (fig. l 2,page 12 ).
➤ Clean the bayonet fitting.
➤ Insert the new seal.
➤ Ensure uniform seating of the new seal.
➤ Place the slider back on.
➤ Grease all areas.
EN
Maintenance