Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Instructions For Assembly; Electrical Safety - FALMEC Domino 38 Gebrauchsanweisung

Vorschau ausblenden Andere Handbücher für Domino 38:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 17
SAFETY DEVICES ON THE COOKER
Safety shutdown
If a cooking area exceeds the maximum time for operation at the same power, it is auto-
matically switched off and the indication of the residual heat is shown.
To reset the cooking area, touch the necessary keys.
1
low
2
Power level
Maximum
duration of
8.7 2.0
8.7
6.7
operation in
hours
The cooker switches off automatically if one or more controls stay covered for more than
10 seconds.
To restore the proper operation:
- remove all objects from the control panel.
- clean the control panel.
- restart the cooker and the concerned area.
Overheating device
Before items of the cooker can overheat, the control reduces the used power by follow-
ing this procedure for protection measures:
- Deactivation of booster and power booster if turned on.
- Reduction of the power level set.
- Shutdown of the cooking area concerned.
On the display of the cooking area the message "E2" is displayed.
It is possible to restore the cooking area when the default message is off.
SAFETY INSTRUCTIONS
FOR ASSEMBLY
Install the cooker after installing kitchen cabinets and basis.
Make sure that worktops have been veneered with thermoresistant glue in
order not to suffer deflections or detachments.
It is forbidden to install the appliance on fridges or freezers, washing ma-
chines, dishwashers, or tumble driers.

ELECTRICAL SAFETY

The electrical system to which the cooker is to be connected must be in
accordance with local standards and supplied with earthed connection in
compliance with safety regulations in the country of use. It must also com-
ply with European standards regarding radio antistatic properties.
Make sure that it can't be possible to touch the power cable of the cooker after it has been
built-in and that it is not subject to mechanical stress.
The socket used to connect the installed equipment to the electrical power supply must
be within reach: otherwise, install a mains switch to disconnect the hood when required.
Any changes to the electrical system must be carried out by a qualified electrician.
Do not try to solve the problem yourself in the event of equipment malfunction, but contact
the Dealer or an authorised Servicing Department for repairs.
When installing the cooker, disconnect the equipment by removing the
plug or switching off the main switch.
3
4
5
6
7
8
9
5.3
4.3
3.5
2.8
2.3
1.9
ELECTRICAL CONNECTION
(only intended for qualified personnel)
Disconnect the equipment from mains power network before carrying out
any operation on the cooker.
Make sure that electric wires inside the cooker are not disconnected or cut:
in the event of damage, contact your nearest Servicing Department.
Refer to qualified personnel for electrical connections.
Connection must be carried out in compliance with the provisions of law in force.
Before connecting the cooker to the mains power network, check that:
the mains voltage corresponds with the voltage indicated on the data plate located
P
inside the cooker;
the electrical system is compliant and can withstand the load (see the technical specifi-
cations located inside the cooker);
the power supply plug and cable do not come into contact with temperatures exceed-
1.5
ing 70 °C;
the power supply system is effectively and properly connected to earth in compliance
with regulations in force.
the socket used to connect the cooker is within reach.
In case of:
devices fitted with cables without a plug: the type of plug to use is a ''standardised'' one.
The wires must be connected as follows: yellow-green for earthing, blue for neutral and
brown for the phase. The plug must be connected to an adequate safety socket.
fixed equipment not provided with a power supply cable and plug, or any other device
that ensures disconnection from the electrical mains, with an opening gap of the con-
tacts that enables total disconnection in overvoltage category III conditions.
Said disconnection devices must be provided in the mains power supply in compliance
with installation regulations.
The yellow/green earth cable must not be cut off by the switch.
The Manufacturer declines all responsibility for failure to comply with the safety regulations.
Connection of the cooker:
network
Connection
230V~
Single-phase
50/60Hz
+ N
* calculated with the contemporary factor in compliance with EN 60 335-2-6.
POWER:
Feature
Total power
Front position
Rated power
Booster power
Back position
Rated power
Booster power (1/2)
13
Cable
Power
Switch
section
cable
gauge
3 x 2.5
H 05 VV - F
25 A *
mm²
H 05 RR - F
38 Plus
38
3500W
3500W
2100W
1600W
1850W
3500W
2100W
2100W
3500W
2100/3000W

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Domino 38 plus

Inhaltsverzeichnis