28
Installation
The installation of more than one appliance
Added parts:connection bar(s), heat resistant silicon, rubber shape, sealing strap.
Only use special a heat - resistant silicon.
The worktop cut out
Distance from the wall : minimum 50 mm
Depth : 490 mm
Width : sum widths of all the appliances to be built-in and subtract 20 mm (see also "Over-
view of all appliance widths" )
Example :
The installation of more than one appliance
1.
Put down the dimension of the worktop cut out and saw it out.
2.
Put the appliances one at time on some soft surface, a blanket for example, with the
bottom side up.
3.
Put the seal stripe around the lower edge of the appliance along the outer edge of the
glass ceramic.
4.
Loosely screw the fixing plates into the appropriate holes in the protective casing.
5.
Put the first appliance in the worktop cut out. Put the connection bar in the worktop
cut out and push up half of the width against the appliance.
6.
Loosely turn in fixing plates from below on the worktop and on the connection bar.
7.
Put the subsequent appliance in the worktop cut out . Make sure that the front ends
of the appliances are on the same level.
+
-
580 mm
360 mm
20 mm
=
920 mm