6.4 Configuring via the service interface
Requirements for Internet browsers:
JavaScript activated
Microsoft Internet Explorer 11 or higher
Mozilla Firefox v30 or higher
Google Chrome v35 or higher
Opera v20 or higher
f Enter the IP address of the device and port (25000) in
the address bar of your Internet browser.
Î "6.3 Network connection"
f Enter PIN3 (installation PIN).
9
The main menu of the service interface opens.
When entering the PIN1 (APP PIN), no changes in
the "Installation Settings" menu are possible.
f Synchronize time.
Î "6.6 Time synchronisation"
A fault message appears on the LED information
field if the time is not synchronized.
The following submenus are displayed:
"Production Settings": display of the manufacturer set-
tings and hardware / software versions.
"Installation Settings": making settings for commission-
ing.
"User Settings": making customer-specific settings.
"Whitelist": defining RFID cards (users).
"System": backup of the settings made, restarting the
device, updating the software.
f Configure the device taking into account the circum-
stances and customer requirements.
f Save the set configuration by clicking the "Submit" but-
ton.
6.4.1 Menu "Production Settings"
The menu "Production Settings" displays factory settings
and the hardware / software versions. You cannot make
any changes here.
Wallbox Data
VALUE
Description
HMI HW Version
Hardware version HMI
HMI SW Version
Software version HMI
HMI Type
HMI type
HMI IO Status
Status of inputs and outputs
HMI Temperature
HMI temperature
Internal [°C]
HMI Temperature
Device temperature
External [°C]
HMI Error Code
HMI error code
RFID Version
Version of the RFID card reader
WLAN Version
Version of the WLAN module
HCC3 HW Version
Hardware version of the HCC 3
HCC3 SW Version
Software version of the HCC 3
HCC3 IO State
Status of the inputs and outputs of
the HCC 3
HCC3 CP/PP State
Status of CP/PP signal contacts
HCC3 Error Code
Error code of the HCC 3
AMTRON
Operating mode of the device
Operation Mode
AMTRON name
Name of the device
AMTRON NDN
Network devices name
AMTRON State
Operating status of the device
AMTRON RS485
Network address of the device with
Address
active RS-485 bus connection (SCU
mode)
AMTRON
Plug-in system of the device
Connector Type
AMTRON No. of
Number of mains phases
Phases
Operating manual AMTRON
Xtra (E/R), Premium (E/R/W) "5.1
Functional description of the
operating modes"
EN
21