3.5 Typical arrangement
Note: This arrangement is only an illustrative example.
3.6 Adjusting the bypass
To pool
Out
How to get the optimum water flow:
Please turn on the heat pump under heating function, firstly close the by-pass then open it slowly to start the heat
pump (the machine can't start running when the water flow is insufficient).
Continue to adjust the by-pass, at the meantime to check the Inlet water temp. & Outlet water temp., it will be
In
Heat Pump
Use the following procedure to adjust
the bypass:
From pool
13
1.Valve 1 wide open. Valve 2 &
valve 3 closed.
2.Slowly open valve 2 & valve 3 by
half, then close the valve 1 slowly
to increase the water flow to valve 2
& valve 3.
3. If it shows 'ON' or 'EE3' on
display, it means the water flow into
heat pump is not enough, then you
need adjust the valves to increase
the water flow through the heat
pump.