INSTALLATION

Commissioning

11. Commissioning

11.1 Initial start-up

1.
2.
3.
(DCE 11/13)
4.
5.
°C
40
30
6.
20
(DCE 11/13)
f Fill the appliance by running the tap until the pipework and
f
appliance are free of air. Open the draw-off valve several
times.
f Activate the electronic safety switch (AE3). As supplied, the
f
electronic safety switch is activated.
f For DCE 11/13 only: Push the temperature selector plug into
f
the "set temperature" PCB. Note the alignment of the lead.
f Fit the appliance cover by positioning it and pressing against
f
it until the locking hooks at the top and bottom click into
place. Check that the locking hooks have clicked into place.
f Switch the mains electrical power ON.
f
f For DCE 11/13 only: Turn the temperature setting knob to its
f
left-hand and right-hand end-stop.
f Remove the protective film from the faceplate.
f
f Carry out a tightness check.
f
f Check the function of the appliance.
f
www.stiebel-eltron.com
≥ 60 s
°C
40
30
50
50
60
20
60

11.2 Appliance handover

f Explain the functions of the appliance to the user. Show the
f
user how to operate the appliance.
f Make users aware of potential dangers, especially the risk of
f
scalding.
f Hand over these instructions.
f

11.3 Recommissioning

Material losses
!
Following an interruption to the water supply, recommis-
sion the appliance by carrying out the following steps.
This will prevent destruction of the bare wire heating
system.
f Disconnect the appliance from the power supply by removing
f
the fuses/tripping the MCBs.
f Open the tap for one minute until the appliance and its up-
f
stream cold water inlet line are free of air.
f Switch the mains electrical power back ON again.
f
f See chapter "Installation / Commissioning".
f

12. Shutdown

f Disconnect the appliance from the mains at the MCB/fuse in
f
the fuse box.
f Drain the appliance (see chapter "Installation /
f
Maintenance").

13. Troubleshooting

WARNING Electrocution
In order to test the appliance it must be connected to the
power supply.
Indicator options for LED diagnostic traffic light
Possible indications of diagnostic traffic light (LED)
Red
Yellow
Green
13kW
11kW
Illuminates in the event of a fault
Illuminates during heating mode
Flashing: Appliance is supplied with
mains power
DCE 11/13 |