3.2

INSTALLATION

The 8045 flow transmitter can be installed into pipes using our specially designed fitting
system S020.
The fitting
must be installed into the pipe according to the installation specifications
within section 3.1.
Insert the plastic nut
guide-bush
Insert the sensor into the fitting ensuring the arrow on the side of the housing
indicates the flow direction, and:
Version with a PVDF sensor: ensuring the sensor is sitting correctly, making
sure that the lug
Version with a stainless steel sensor: ensuring the cable glands show the
downstream direction and the alignment of the electrodes is perpendicular to
the flow direction.
If the mounting is correct, the sensor housing
The plastic nut must only be tightened by hand!
INSTALLATION
DEUTSCH
onto the fitting
.
is aligned correctly onto the fitting.
Flow direction
Fig. 3.1 Installation of flow transmitter
and snap the plastic ring
cannot be rotated.
(PVDF sensor only)
10
into the
8045