6. Water discharge pipe
Pull the air outlet pipe apart by pulling on both ends.
Screw the air outlet pipe to the square-shaped appliance connector.
Screw the other end of the air outlet pipe into the round wall connection
fitting.
Connect the square appliance connector to the air conditioner
.
AUTOMATIC SAFETY FUNCTION
The automatic safety function can switch the appliance off if any of the following
takes place:
Cooling
Dehumidify
If your appliance is set to Cool or Dehumidify and the window remains open for a
considerable length of time and the relative atmospheric humidity is above 80%,
liquid may run out of the water outlet.
Applicability of the Safety Function
If the appliance is restarted immediately after it is switched off the automatic safety
function will not allow the appliance to work immediately. Always wait for 3 minutes
before restarting the appliance. If you remove the plug from the socket, the appliance
rests itself to the original settings. The 'Timer on' and 'Timer off' settings must be
readjusted.
DRAINAGE
The appliance has a receptacle (container) for collecting water for recycling.
When the water level is below the minimum level indicated on the collector the pump
for recycling water will not run. When the water level rises above the minimum level
the pump will start to recycle. If the water level rises above the maximum level, E4
will be visible on the display to indicate that the collection receptacle is full. You can
empty the container by opening the drainage opening at the bottom of the appliance.
Make sure that you place a collection container under the opening beforehand.
Indoor temperature rises above 43°C
Room temperature is below 15°C
Room temperature is below 15°C