4. CHARACTERISTICS
4.1
Reference conditions
Quantities of influence
Temperature
Relative humidity
4.2
Characteristics at the reference conditions
The uncertainty is expressed in the form x% of the reading + y
point(s).
4.2.1 Insulation resistances
250V
1mA test current into a 250k
Range
Resolution
4M
0,001M
40M
0,01M
400M
0,1M
4G
1M
Mean battery life > 50h.
500V
1mA test current into a 500k
Range
Resolution
4M
0,001M
40M
0,01M
400M
0,1M
4G
1M
Mean battery life > 50h.
1000V
1mA test current into a 1M
Range
Resolution
4M
0,001M
40M
0,01M
400M
0,1M
4G
1M
Mean battery life > 50h.
Reference conditions
23° C ± 2° C
45% to 75%
load.
Uncertainty (±)
2% +10 pts
2% +10 pts
3% +5 pts
4% +5 pts
load.
Uncertainty (±)
2% +10 pts
2% +10 pts
2% +5 pts
4% +5 pts
load.
Uncertainty (±)
3% +10 pts
2% +10 pts
3% +5 pts
4% +5 pts
31