5.4 Time mode
•
If the remote control display shows °C or °F, press MODE to select TIME MODE.
The remote control display shows 't' in TIME MODE.
•
Press UP or DOWN to adjust the time in steps of 0.1 minute.
•
Press POWER to select the power level. Use the guidelines in section 5.8 to
determine the correct power setting.
•
Press START / STOP to start the heater. The remote control display shows the time
that remains.
•
During heating, the temperature measured by the probe can be displayed for a couple
of seconds by pressing MODE.
•
When the time has elapsed, the heater demagnetises the workpiece, switches off, and
generates an acoustic signal for 10 seconds.
•
Press START / STOP to cancel the acoustic signal and stop the heater.
•
Remove the workpiece with proper handling equipment.
•
The TIH 100m is now ready to heat another workpiece with the same settings.
5.5 Temperature measurement
When the heater is not operating, the temperature of the workpiece can be measured by
pressing MODE and START / STOP at the same time. The LED on the START / STOP button
lashes during temperature measurement. Press START / STOP to cancel temperature
measurement.
5.6 Change of temperature unit
Press MODE and UP at the same time to switch between °C and °F. The temperature unit
setting remains the same even after disconnection from mains power.
5.7 Demagnetisation
The workpiece is automatically demagnetised when heating is complete.
Demagnetisation will not occur if the power is interrupted or the main switch is switched
off. To use the TIH 100m for demagnetisation only, select TIME MODE and set the time to
0.1 minute (6 seconds).