Herunterladen Inhalt Inhalt Diese Seite drucken

Precautions For Use - Metrix MX2B Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 20
Meaning of symbol
C A U T I O N ! P l e a s e c o n s u l t t h e o p e r a t i n g i n s t r u c t i o n s b e f o r e u s i n g
t h e d e v i c e . I n t h e s e o p e r a t i n g i n s t r u c t i o n s , f a i l u r e t o f o l l o w o r c a r r y
o u t i n s t r u c t i o n s p r e c e d e d b y t h i s s y m b o l m a y r e s u l t i n p e r s o n a l
i n j u r y o r d a m a g e t o t h e d e v i c e a n d t h e i n s t a l l a t i o n s .
Meaning of symbol
T h i s a p p l i a n c e i s p r o t e c t e d b y d o u b l e i n s u l a t i o n o r r e i n f o r c e d
i n s u l a t i o n . I t d o e s n o t h a v e t o b e c o n n e c t e d t o a n e a r t h p r o t e c t i o n
t e r m i n a l f o r e l e c t r i c a l s a f e t y .
Thank you for purchasing this MX2B multimeter.
To obtain the best service from your unit:
Read these operating instructions carefully,
Comply with the precautions for use.
Never use on a voltage network over 600V with respect to the earth connection.
This voltage surge category III multimeter complies with stringent reliability and
availability requirements, corresponding to fixed industrial and domestic
installations (see IEC 664-1).
Do not use on alternative and continuous voltages > 600V.
Indoor use in environments with a maximum pollution level of 2 (cf. IEC 664-1),
temperature of -10°C to +50°C and relative humidity below 90%.
Respect the value and type of the fuses to avoid damaging the instrument and
cancelling the warranty.
1.6A HPC fuse (6.3 x 32mm) 600V - 50kA
10A HPC fuse (6.3 x 32mm) 600V - 50kA
Use accessories corresponding to safety standards (EN 61010 - 031) with 600V
minimum voltage and surge category III.
Before any measurement, ensure correct positioning of the leads on the
multimeter and of the switch. When the value range of a measurement is not
known, place the switch at the highest calibre, then gradually reduce it until the
appropriate calibre is achieved: the reading should preferably be in the upper 2/3
of the range.
Never measure resistances on a live circuit.
During current intensity measurements (without a clip-on ammeter), stop circuit
power supply before connecting or disconnecting the multimeter or changing
calibre.
The leads must be disconnected to open the lower half of the MX2B casing.
Never connect to the circuit to be measured if the casing is not properly closed.

PRECAUTIONS FOR USE

10

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis