77
IStick QC 200W - Error Messages & Protection Functions
Over 10 sec Protection
If you press and hold down the Fire button for more than 10 seconds, the unit will automatically
switch off� The display will show "Over 10s"�
Atomizer Low Alarm
If the resistance of the coil in VW or Smart mode drops below 0�1 ohm or in TC mode below 0�05
ohm, the display will show "Atomizer Low"�
Surge Protection & No Vaporizer Head Detected
If a power surge occurs on the vaporizer, the display shows "Atomizer Short"� "No Atomizer" will
appear on the screen when no vaporizer is connected�
Low-Voltage Protection
If the voltage of the battery drops below 3�3 volts, the display will show "Battery Low" and then
"Lock"� Charge the battery to unlock the device�