Before starting the dehumidifier, make sure that the machine has been standing in vertical position for at-least 8 hours. If one
fails to observe this procedure, irreparable damage may be caused to the compressor. Then one can proceed and connect
the dehumidifier plug to a 230 V - one phase power socket.
The red light 'POWER' will switch on confirming correct supply of power to the machine. If the light 'WORKING' is still off, turn
clockwise the knob on the control panel till the light 'WORKING' is ON. The light 'DEFROST (PAUSE) will also switch on and
, after about 5 minutes the dehumidifier will start dehumidifying.
When the red light is "ON" (ALARM), the machine wiil not start: one must check that the water tank be empty and, then, that
be set in correctly; with the machines provided with pump, check that the pump function be working and that the delivry pump
may be clear.
AND IF THE DEHUMIDIFIER DOES NOT START OR DEHUMIDIFY ?
First make sure that the red light 'POWER' is 'ON': this means that the current is fed to the machine. If the power supply light
is not on, make sure that the connecting wire plug may be properly inserted into a main line socket in the room. After
checking all this, if the power light is still off, then call the dealers service.
Make sure that the green light 'FULL' be off; If this is not the case, check the correct position of the draining pipe (see point
4.)
Make sure that the red light 'RUNNING' be 'on'; this means that the Humidostat activates the functioning of the machine.
When the dehumidifier is set again to functioning, after an idle period due to the reaching of the preset humidity or after
emptying the water tank, if the Humidostat requires functioning of the machine, then beside the two red central lights, also
the red light 'Pause' will light up. During this 5 minutes long phase, only the motor fan is running whereas the compressor is
off. This operating cycle take place every 45 minutes to allow the defrosting of the cooler. When the red light 'Pause' will
remain off for a period longer than 6 minutes, the dehumidifier should be brought to Dealer's service centre.
When the machine appears to be working correctly ( the two central red lights are on), but it is not producing condensed
water or produces only very little condensed water, it should be checked whether the relative humidity in the room may be
lower than 40.45%; if the relative humidity is higher than that, the machine should be controlled by the dealer's service.
6. CONNECTION TO A DRAIN PIPE - LIFTING PUMP (optional)
This dehumidifier a
This dehumidifier can be connected directly with a fixed draining
pipe; in this case, the water tank must be removed to allow for the
connection of the pipe to the connection fitting.
For the connection, use one pipe provided with a ¾" female fitting
at one end.
In the machines with ball-cock, if the water tank is not fitted in,
the machine will not work.
Some have machines have a switch in order to allow the
functioning without water tanks, in other machines one must
modify the tongue-shaped device placed near the ball-cock.
In the machines with tank placed in the front, one special fitting,
which is supplied with the machine, must be placed on the right
upper side of the water tank room, and must be used also the
supplied rubber device to block the microswitch lever which is
located on the left upper side of the water tank towards the front
part.
HOUR COUNTER
Some models are equipped with an Hour Counter which is normally
located in the rear side of the machine: this will show the hours that the
machine has been
.
. FIRST STARTING OF MACHINE
5
working.