The grinding fineness button is
difficult to turn.
Steam does not come out of the
nozzle.
Not enough froth on the milk.
The milk froth is too bubbly.
The Auto-Cappuccino accessory
does not suck up the milk
(accessory sold separately)
The cleaning or descaling program
will not start.
After having filled the water tank,
the
light remains on.
After having emptied the coffee
grounds collector, the
remains on.
A power failure occurred during a
cycle.
There is water or coffee under the
appliance.
The 4 red lights flash permanently.
Only adjust the grinder when it is operating.
After switching off your appliance and leaving it to cool:
Make sure the tip of the steam nozzle is properly affixed. Make sure the steam
nozzle is not clogged at the aerator (if necessary clean the steam nozzle aerator
with the needle supplied). Empty the tank and remove the Claris filter. Fill the tank
with mineral water high in calcium (> 100 mg/litre or .015oz/gallon), it may take as
many as 5 to 10 cycles of steam at 60 seconds each cycle to achieve a continuous
jet of steam. Once you have a continuous jet of steam you should not have to use
this particular type of water again.
Using the needle supplied unblock the small air inlet at the top of the nozzle if
required.
Use a cold container and milk that has been opened recently.
Try changing the type of milk if this does not work (UHT or pasteurised).
Check that the 2 ends of the small stainless steel tube in the flexible part of the
steam nozzle are fitted together properly.
Check that the tube that goes into the milk is not blocked.
Check that the flexible tube is not twisted and that it is correctly fitted into the
accessory to avoid any air being sucked in.
After having turned the machine off and left it to cool, unblock the outlet of the
Auto-Cappuccino accessory.
These programs are only possible when the machine requests them ('clean' or
'calc' light on).
Check for correct positioning of the tank in the coffee maker.
Check that the float at the bottom of the tank moves freely.
Rinse the accessory and if necessary remove scale.
Remove the collector, make certain that it is empty, wait for 6 seconds and then
light
fit it again.
Check that the cleaning tray is correctly pushed in.
The appliance will re-initialise automatically when power is turned on and be ready
for a new cycle.
The drip tray has overflowed: empty it and clean the cleaning drawer.
Check that the drip tray is fitted correctly.
Do not remove the water tank before the end of the cycle.
Unplug the machine, remove the Claris cartridge, wait for 20 seconds and then
turn it all back on.
If the fault persists, note the number which appears on the display under the cup
tray and contact the Krups Consumer Service.
9