H. Pumps must be either
- supplied by an isolating transformer, or
- supplied through a residual current device (RCD) with a rated residual operating current not exceeding
30mA.
Warning: - It is essential that you use a multiple disconnection device with a space of at least 3 mm between
surfaces to disconnect the equipment from the electrical current.
- Use a rigid cable to connect to the mains. If you use a flexible cable to connect to the mains, it must have
cable lugs to connect to the terminals of the pump motor.
- The equipment should be connected to an alternating current supply (see data on the pump's plate) with
earth
connection, protected by a residual current device (RCD) having a rated residual operating current not
exceeding 30 mA.
- Adjust the value of the thermal relay appropriately depending on the pump current.
- Before connecting the motor, check the type of fuse required.
Viron pumps include PCB's and microchips. It is necessary to turn power off completely for 10 seconds
before turning pump back on again. Some brands on chlorinators may bleed a small amount of power into
the Viron Pump even when the pump off mode is selected. If this occurs, the Viron Pump may not reset
correctly and may not start until power is disconnected completely. In some cases, the manufacturer of
these chlorinators may be able to remove or change a capacitor which will completely disconnect power to
the pump when turned off. If not, a suitable chlorinator may be required to be purchased. Astral Pool
chlorinators completely disconnect power to the pump when the pump off mode is selected.

OPERATION

1.
Prime pump if hair and lint pot is dry as follows – Close off valve on suction line if present. Remove lint pot
lid. Fill lint pot and chamber with water. Replace and secure lint pot lid and seal.
2.
Open all valves, allowing water to flow through pump.
3.
Switch on power to pump, motor to start.
4.
If some flow of water does not establish within on half minute, switch off and prime pump again. If pump
does not prime within 3 attempts, check all suction connections for sealing. If these are satisfactory, a
check or foot valve is required to hold water for prime.
5.
If the water flow through pump is always tedious to obtain at start-up after cleaning the lint basket, then
an examination of the system to establish a reason and correct the cause is recommended. Eg. Check
valve, air leaks, faulty seal, cracked lint pot lid, etc.
6.
The Viron EVO has 3 factory preset speed settings – Low, Medium and High. High should be used when
backwashing, manually vacuuming the pool or operating spa jets or some water features such as
waterfalls. Medium speed can be used for gentle spa jet action, when suction cleaner is connected to the
skimmer or filtration for the pool. Low is the recommended setting for everyday filtration of your pool
when a cleaner is not connected.
7.
The Viron EVO will automatically start on High for the first 5 minutes to assist in priming and substantially
fill the hair and lint pot with water. After 5 minutes the pump will revert to the last speed it was set at
before it was turned off.
INST 341 Installation and General Maintenance Manual – Viron eVo Pool Pump V11-14