Read the operating instructions and the enclosed brochure
!
„Guarantee and additional notices" completely. Follow the
instructions they contain. This document must be kept in a
safe place and passed on together with the device.
Function/Application
Multimeter for taking measurements in the range of overvoltage
category CAT III up to max. 300 V. The meter can be used to
measure DC and AC voltages and direct and alternating currents
within the specified ranges, as well as for continuity and diode
testing.
Symbols
Hazardous electrical voltage warning:
Unprotected live components inside the device
housing may pose a risk of electric shock.
Danger area warning
Protection class II: The test device has
reinforced or double insulation.
Overvoltage category III: Equipment in fixed installations
and for applications where specific requirements with
regard to the reliability and availability of equipment
have to be met, e.g. circuit-breakers in fixed installations
and devices used in industrial applications which are
permanently connected to the fixed installation.
Safety instructions
• The device must only be used in accordance with its intended
purpose and within the scope of the specifications. Modifications
or changes to the device are not permitted, this will otherwise
invalidate the approval and safety specifications.
• In overvoltage category III (CAT III), the voltage between the test
device and earth must not exceed 300 V.
• Do not expose the device to mechanical stress, extreme temperatures
or significant vibration.
• If you are working with voltages higher than 25 V AC / 60 V DC,
exercise extreme caution. Touching the electrical conductors at
such voltages poses a risk of life-threatening electric shocks.
• If the device comes into contact with moisture or other conductive-
residue, work must not be carried out under voltage. At and above
voltages of 25 V AC / 60 V DC, the presence of moisture creates
the risk of life-threatening electric shocks. Clean and dry the device
before use. When using the device outdoors, make sure that the
MultiMeter-PocketBox
09
EN