Herunterladen Inhalt Inhalt Diese Seite drucken

Mesto REKORD 3533S Gebrauchsanleitung Seite 16

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
GB
IRL
Pressure valve
d) Using the filling strainer [9], rotate the pressure valve screw [24] counter-clockwise.
(Fig. 15)
Intake valve
d) Rotate the cylinder [19] 90° counter-clockwise and take it out of the tank. (Fig. 17)
e) Using a screwdriver (starting at the recess [26]), detach the intake valve [27] from the
cylinder [19]. (Fig. 18)
Re-assembly:Position the cylinder [19] on the intake valve [27] (opening [30] exactly
over the mushroom of the pressure relief valve [28], Fig. 20) and press the cylinder [19]
and the intake valve [27] together (Fig. 21)
Faults
Use only MESTO spare and accessory parts.
(Remove pressure vessel → section "Care and maintenance" chapter)
Fault
No pressure builds up in
the device.
Lever [11] can be moved
very easily.
Lever [11] is pulled
downwards.
Lever [11] is pulled
upwards.
Lever [11] locked or can
be moved downwards
with difficulty only.
AUS
USA
Cause
Diaphragm [17] is defective.
Foreign object prevents closure
of the pressure valve [24] or
intake valve [27]
Valve disc [29] of the intake
valve defective.
Pressure relief valve [27] dirty.
Intake valve [28] sticking.
Foreign object prevents closure
of the pressure valve [24] or
defective valve disc [25].
Diaphragm [17] is defective.
Pressure valve [24] dirty.
Filter [20] or / and nozzle [22]
blocked.
16
NZ
CDN
Remedy
Replace the diaphragm. (Fig.
16)
Clean intake or pressure valve
(Figs. 16 and 19)
Replace valve disc. (Fig. 19)
Clean pressure relief valve.
(Fig. 19)
Clean intake valve. (Fig. 19)
Clean pressure valve
or replace valve disc. (Fig. 16)
Replace the diaphragm. (Fig.
16)
Clean pressure valve. (Fig. 16)
Clean filter (Fig. 13) or / and
nozzle (Fig. 14).
IND