6- INSTALLATION
6.4-
ELECTRICAL CONNECTIONS (Wiring diagram)
THE ACTUATOR MAY ONLY BE CONNECTED TO THE POWER SUPPLY BY
COMPETENT AND QUALIFIED TECHNICAL PERSONNEL (ELECTRICIANS) WHO
SATISFY THE PROFESSIONAL AND TECHNICAL REQUIREMENTS ESTABLISHED
BY THE LAWS IN FORCE IN THE COUNTRY OF INSTALLATION AND WHO CAN ISSUE
THE CUSTOMER WITH A DECLARATION OF CONFORMITY COVERING THE
RELATIVE CONNECTION AND/OR SYSTEM.
BEFORE CONNECTING THE ACTUATOR TO THE POWER SUPPLY, CHECK IT IS
CORRECTLY FITTED TO THE WINDOW FRAME.
THE MAINS POWER SUPPLY TO WHICH THE ACTUATOR IS CONNECTED MUST
SATISFY THE REQUIREMENTS ESTABLISHED BY THE LAWS IN FORCE IN THE
COUNTRY OF INSTALLATION, AS WELL AS THE TECHNICAL SPECIFICATIONS
INDICATED IN TAB. 1, THE RATING PLATE AND THE "CE" MARKING (PARA 3.1).
THE CROSS-SECTION OF THE MAINS LINE MUST BE PROPERLY SIZED
ACCORDING TO THE POWER INPUT (SEE RATING PLATE AND "CE" MARKING).
ANY TYPE OF ELECTRIC MATERIAL (PLUG, CABLE, TERMINALS, ETC.) USED FOR
THE CONNECTION MUST BE SUITABLE FOR USE, "CE" MARKED AND SATISFY THE
REQUIREMENTS ESTABLISHED BY THE LAWS IN FORCE IN THE COUNTRY OF
INSTALLATION.
A SECTIONING DEVICE WITH A 30 mA DIFFERENTIAL PROTECTION AND
ASSOCIATED WITH THE EARTH CIRCUIT MUST BE INSTALLED UPLINE FROM THE
POWER LINE.
IT IS FORBIDDEN TO CONNECT ACTUATORS FITTED WITH DOUBLE INSULATION
(MOD. 230V) TO THE EARTH CIRCUIT.
TO ASSURE EFFICIENT SEPARATION FROM THE MAINS, INSTALL AN APPROVED
TEMPORARY BIPOLAR SWITCH (PUSH-BUTTON) UPLINE OF THE DEVICE. FIT A
BIPOLAR MAIN SWITCH WITH CONTACT APERTURE OF AT LEAST 3.5 mm UP LONE
OF THE CONTROL LINE.
6.5-
CONTROL DEVICES
THE CONTROL DEVICES USED TO DRIVE THE ACTUATOR MUST SATISFY THE
SAFETY CONDITIONS ESTABLISHED BY THE LAWS IN FORCE IN THE COUNTRY OF
INSTALLATION.
Depending on the various types of installation, the actuators can be driven by the
following control devices:
1) MANUAL PUSH-BUTTON:
Two-pole push-button switch with central OFF position and "dead man" control.
38