Herunterladen Inhalt Inhalt Diese Seite drucken

Simolink Data Interface - Siemens SLP – SIMOLINK Puls Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

SIMOLINK Pulse Generator
6.3

SIMOLINK data interface

31
Evaluated by the SLP
32-bit setpoint
(hex)
47C0 0000
4780 0000
4000 0000
0000 0000
C000 0000
B880 0000
B840 0000
NOTICE
Siemens AG
GWE-477 764 4070.76 J
SIMOVERT MASTERDRIVES
02.2001
The SIMOLINK data interface comprises a single-channel SIMOLINK
receive data word; it does not provide a transmit channel. It expects the
speed setpoint for the frequency generator in receive channel 0 of the
set receive address. The setpoint is read in the MASTERDRIVES 32-bit
format (4000 0000 hex = 100 %); only the 10 highest bits are resolved,
corresponding to a speed resolution of 0.4 %.
32-bit setpoint from SIMOLINK receive telegram
22
Fig. 6-3
SLP setpoint telegram
The frequency generator has a frequency range of 0 Hz to 112 kHz (at
a rated frequency of 100 kHz). In the 90° pulses mode (4 edges
required for correct signal sequence from tracks A and B), the resulting
rated output frequency per track is 25 kHz and a maximum possible
setpoint output of approximately 112 %.
Setpoint
Output frequency in
[%]
90°pulses mode [kHz]
+ 112.1
28.027
+ 111.7
27.930
+ 100.0
25.000
0.0
0.000
− 100.0
25.000
− 111.7
27.930
− 112.1
28.027
Table 6-3
Relationship between setpoint and output frequency
When the setpoint exceeds 112 %, the SIMOLINK Pulse Generator
outputs the maximum frequency of approximately 28 kHz. If "100 kHz
signal" mode is active, then approximately 112 kHz.
Operating Instructions
16 15
Irrelevant
100 kHz / sign mode
Start-Up
Frequency in
112.1 kHz / Low
111.7 kHz / Low
100.0 kHz / Low
0.0 kHz / Low
100.0 kHz / High
111.7 kHz / High
112.1 kHz / High
6-3