Connecting to the back
For a connection to the rear, the position of the con-
nection collar needs to be changed. The connection
collar is attached with 2 M8 nuts (key 13). Proceed as
follows:
Disassembly (see previous drawing)
1. First remove the baffle plate.
2. Remove the cover (7) from the back wall by remov-
ing the nut (6) and the clamping bracket (9).
3. Remove the cover (7) and the seal (8).
Check that the sealing tape on the contact sur-
face is not damaged. Replace the sealing tape
if it is damaged.
4. Disassemble the connecting collar (2) by undoing
the bolts (1).
5. Remove the connection collar (2), the seal (3) and
the materials supplied (1, 5, 6).
Check that the sealing tape on the contact sur-
face is not damaged. Replace the sealing tape
if it is damaged.
6. Remove the brake plate (4).
10
5
6
9
4
8
7
09-20021-100
Assembly (see drawing below)
A
7
8
9
6
5
1. Remove the top plate (A).
2. Assemble the decorative cover (B) using the
materials supplied (C).
3. Fit the connecting collar (2), the seal (3) and the
brake plate (4) with the materials supplied (1, 5, 6)
on the back wall
4. Assemble the connection collar (7) and the seal (4)
with the materials supplied (8, 9, 5, 6).
5. Place the top plate (A) with assembled decorative
cover (B) on the appliance and note the positioning
ridges.
Preparing the outside air
connection
If the appliance is installed in a room with insufficient
ventilation, you can install the outside air connecting
kit to the appliance.
The air supply tube is 100 mm in diameter. If the tube
is smooth, it may be no longer than 12 metres. If
accessories such as bends are used, the maximum
length (12 m) must be reduced by 1 m for each access-
ory used.
Outside air connection via the wall
1. Make an opening in the wall (see the appendix,
"Measurements", for the correct position of the
opening).
2. Close the air connection hermetically to the wall.
Subject to change because of technical improvements
B
C
4
3
2
1
09-20021-101