Technical data
Parameter
Frequency
Voltage
Power rating (EN 60335-2-69) (50 Hz)
Noise level (Lpf) (EN60335-2-69)
Protection
Insulation
Container capacity
Inlet (diameter)
Vibration, a
(*)
h
Max vacuum
Max air flow rate
(without hose and reductions)
Max air flow rate
(with hose, length: 3 m, diameter: 50 mm)
Main filter surface
Absolute filter surface - HEPA 14 according to MPPS method (EN 1822)
Absolute filter surface - ULPA 15 according to MPPS method (EN 1822)
(1) By using cable clamps granting the same IP protection or higher, correctly installed.
(2) If the ground cable has been properly connected by the installer.
(*) Total value of vibration output to the operator arm and hand
Dimensions
Figure 4
VHW200
Model
-
A (mm)
415
B (mm)
530
C (mm)
270
Weight (kg)
17
[ NOTE ]
■
Storage conditions:
Temperature: -10°C ÷ +40°C
Relative humidity: ≤ 85%
■
Operating conditions:
Maximum altitude: 800 m
(Up to 2,000 m with reduced performances)
Temperature: -10°C ÷ +40°C
Relative humidity: ≤ 85%
01/2015
VHW201
-
820
420
430
25
7
VHW200 - VHW201 - VHW210 - VHW211
Units
VHW200
Hz
50
V
400
kW
0.45
dB(A)
56
IP
55(1)
Class
I(2)
L
1
mm
40
m/s
≤2.5
2
hPa - mbar
148-148
m
/h - L/min'
71.5 - 1192
3
m
/h - L/min'
70 - 1167
3
m
0.133
2
m
1.1
2
m
1.1
2
VHW201
50
400
0.45
56
55
I
6.5
40
≤2.5
148-148
71.5 - 1192
70 - 1167
0.184
1.1
1.1
GB
C411