PROGRAM TIMER operation
■ The timer operations of the combination of ON and OFF TIMER. Once this has been set the timer operations will be repeated at the same time every
day unless the ON/OFF button is pressed.
Comfort Start-up
In ON TIMER operation, the unit starts the operation a little earlier, so that the
room can approach optimum temperature at ON time. This is so called
"Comfort start-up".
• Mechanism
The room temperature is checked
60 minutes before the ON time.
Depending on the temperature at
that time, the operation starts 5 to
60 minutes before the timer is at
ON.
• The function is available for both
COOL and HEAT operation
mode (including AUTO). It does
not work for DRY mode.
ALLERGEN CLEAR operation
In COOL operation
(Stop) Operation starts
(Operation)
Set temperature
Check the room
Set time
temp. 60 mins.
before.
■ The power of enzymes is used to eliminate allergy-causing allergens that accumulate on
the allergen clear filter.
1
• Since the room temperature may change quite a bit, it is recommended that this
be used when no one is in the room. (It completes automatically in approxi-
mately 90 min.)
• During ALLERGEN CLEAR operation temperature, fan speed, airflow direc-
tion and timer operations settings cannot be made.
Example: When it is prefered to stop at 22:30, and then start operation at 8:00, near the
set temperature.
■ OFF TIMER operation setting
Set by the procedures on page 11.
■ ON TIMER operation setting
Set by the procedures on page 12.
Timer light (yellow) on the unit will light when the setting is completed.
The set time will be displayed on the remote control unit. The display will
change depending on the operational status.
With ON TIMER, the air conditioner starts running. Then,
with OFF TIMER, the air conditioner stops running.
With OFF TIMER, the air conditioner stops running. Then,
with ON TIMER, the air conditioner starts running.
Changing of set time
Set a new time by using the OFF TIMER or ON TIMER button.
How to cancel
Press the CANCEL button to turn off the timer display.
When SLEEP TIMER is selected, the set temperature is automatically
adjusted after a while, ensuring that the room is not too cold during cooling or
too warm during heating.
• During cooling : the preset temperature is lowered by 1°C at the start of
SLEEP operation (when the timer is set). After that, the temperature goes
up by 1°C every an hour to become 1°C higher than the present
temperature.
• During heating: Preset temperature is lowered by 1°C at the start of SLEEP
operation (when the timer is set). After that the temperature to becomes
3°C lower in an hour and 6°C lower in two hours than the present
temperature.
Aim the remote control at the air-conditioner.
Press the ALLERGEN CLEAR button.
To stop:
NOTE
– 13 –
Set to
Set to
SLEEP TIMER
Press the ON/OFF or
ALLERGEN CLEAR button.