7

Technical data

7.1

Accuracy

The specifications are typical values for BTL6-U... at
24 V DC and room temperature, with a nominal length of
500 mm in conjunction with the BTL5-P-3800-2,
BTL5-P-4500-1, BTL5-P-5500-2, BTL6-A-3800-2,
BTL6-A-3801-2, BTL5-F-2814-1S or BTL5-T-2814-1S
magnet.
The BTL is fully operational immediately, with full accuracy
after warm-up.
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
Resolution
Repeat accuracy
Sampling rate (dependent on the
nominal length)
Non-linearity with a constant distance
between the magnet and profile
Nominal length ≤ 500 mm
Nominal length > 500 mm
Temperature coefficient
(nominal length = 500 mm,
magnet in the center of the
measuring range)
Max. detectable velocity
7.2

Ambient conditions

Operating temperature
Storage temperature
Humidity
Shock rating
per EN 60068-2-27
1)
Continuous shock
per EN 60068-2-29
1)
Vibration
per EN 60068-2-6
1)
Degree of protection
per IEC 60529
(when attached)
16
english
5 µm
≤ 30 µm
Max. 1 kHz
±200 µm
±0.04 % FS
≤ 30 ppm/K
10 m/s
-25°C to +70°C
-40°C to +100°C
< 90%, non-condensing
50 g/6 ms
50 g/2 ms
12 g, 10 to 2000 Hz
IP67
7.3

Supply voltage (external)

Voltage, stabilized
2)
Ripple
Current draw
(at 24 V DC)
Inrush current
Reverse polarity protection
Overvoltage protection
Dielectric strength
(GND to housing)
7.4

IO-Link interface

Transfer protocol
Transfer rate
Cycle time min.
Master-device process data
Device-master process data
PD cycle on 1.0 master min.
PD cycle on 1.1 master min.
Output value
Data format
Error value
7.5

Dimensions, weights

Housing height
Nominal length
Weight (depends on length)
Housing material
Individual specifications as per Balluff factory standard
1)
For
: The transducer must be externally connected via a limited-
2)
energy circuit as defined in UL 61010-1, a low-power source as defined in
UL 60950-1, or a class 2 power supply as defined in UL 1310 or
UL 1585.
18 to 30 V DC
≤ 0.5 V
PP
≤ 150 mA
≤ 3 A/0.5 ms
Up to 36 V
Up to 36 V
500 V DC
IO-Link 1.1
COM3 (230.4 kBaud)
1 ms
0 bytes
4 bytes
4 ms
1 ms
Position in µm
32-bit signed
0x7FFFFFFF
20.8 mm
50 to 4572 mm
Approx. 1 kg/m
Anodized aluminum