15. ERROR MESSAGES

The Power Peak E1 is equipped with a
range of safety features designed to ensure
that the charge and discharge processes
start and finish safely. As soon as an error
occurs, a corresponding message appears
on the screen, and the charger emits an
audible alert.
Once the cause of the problem has been eli-
minated, all the following error messages
can be cancelled by pressing any button.
Input voltage too low (less than 10 Volts).
Check the car battery or mains PSU.
The battery is connected with reversed
polarity. Check the connections.
Battery voltage or output voltage too high;
check cell count.
The charger also checks the cell count via
the equalizer socket, and compares the set-
ting with the value set in the Battery data
menu. If these values do not coincide, this
error message is displayed.
Operating instructions
Power Peak E1
The set cut-off temperature has been rea-
ched, and the charge process terminated.
The BID chip or key has been disconnected
from or connected to the charger while a
process was running. Check the chip con-
nection, and re-start the process.
If the charge / discharge process does not
start after you have connected a BID chip or
key, that could mean that the data on the
chip is corrupt.
This warning also appears if a new (unfor-
matted) chip is connected.
The BID data is entered in the Battery
Settings menu.
The BID chip or key contains no data, or
incorrect data.
The BID chip contains fewer or different
parameters than are available in the Battery
Settings menu. Set the missing data.
Check the settings of the BID chip or key.