Auxiliry ooling X
Emergeny
Support
3.13. DHW/LEGIONELLA PROT. Menu
User menu
/
Refrigerin
DHW/Legionell prot
Pool
/
DHW
Enble
Remote ontrol ON
SetT
DTstrt
SetT HTR
Auxiliry DWH X
Emergeny
Support
DHW reirultion
Enble
SetT
DTstrt
ON
ON
ON
OFF
Legionell
Enble
Strt time
C
Mon
Tue
Wed
Thu
Fri
St
Sun
Auxiliary cooling X
This is used to enable the auxiliary cooling system in both EMERGENCY and SUPPORT
mode.
In EMERGENCY mode, the auxiliary system is activated automatically if there are any
active alarms that prevent compressor start-up.
In SUPPORT mode, the auxiliary system is activated automatically for normal COOL AIR
production, as programmed by the technical service.
DHW
This is used to enable the DHW mode and adjust the setpoint temperature and start-up
C
temperature differential for the DHW storage tank. It is also used to adjust the setpoint
C
temperature for DHW heating with the HTR system.
C
The
icon indicates that there is a time schedule activated in the DHW mode.
Auxiliary DHW X
This is used to enable the auxiliary DHW system in both EMERGENCY and SUPPORT mode.
In EMERGENCY mode, the auxiliary system is activated automatically if there are any
active alarms that prevent compressor start-up.
In SUPPORT mode, the auxiliary system is activated after the compressor when the latter
cannot reach the target DHW storage tank temperature.
DHW Recirculation
C
This is used to set up as many as 4 time periods per day for DHW recirculation.
C
In versions for ecoGEO HP, it can also be used to adjust the start-up setpoint temperature
and the start-up temperature differential for DHW recirculation.
Legionella protection program
This is used to set up a weekly program for protection against legionella.
The legionella protection program is deactivated automatically if 5 hours have elapsed
without reaching the final temperature set up by the technical service.
Legionella protection programs should be carried out at night, or when there is no DHW
consumption.
45
User manual ecoGEO