Instructions of use
Control panel
The FT 80 RLA has various modes and is configured using the S and T buttons.
Button
Set button:
Toggle button: Select a function (proceed to the next function)
The selected settings and signal condition are indicated by LEDs.
Illustr. 9
15500144
The table of functions on page 32 explains the further significance of the LEDs: Q
General use
The following four steps are used to configure the FT 80 RLA sensor:
1. Activate setting mode
Press the S and T buttons simultaneously for 3 seconds
After this period, the power supply indicator BA flashes
set FT 80 RLA, see Illustr. 9. The LEDs show the status of function no. 1 (page 32)
When all the LEDs start immediately flashing
Unlock FT 80 RLA, see paragraph "Unlocking keys" on page 34
2. Select functions (see page 32)
Press the T button to select the next function in the function table.
The function number is indicated by a clear LED pattern and the function status is indicated by the status indicator ZA
(LED on = active, LED off = not active).
The sensor only switches to the next function when the T button is released.
30
Change / confirm a setting or set a switching point
LED
Colour
BA
Green
ZA
Red
Q
Yellow
1
Q
Yellow
2
H
Green
OK
Green
T
Green
Z
Green
Use/Description
Power supply indicator
On: ready (run mode)
Flashing: setting mode is active
Status indicator
Function activated/not activated, or confirmation signal
Q
input/output
1
Q
output
2
Q
trigger input or Q
enable input function active
1
1
Good target (object detected and in measuring range)
Pulse stretching function is active
Q
automatic centre or Q
1
FT 80 RLA Distance sensor - 068-13715 - 04.05.2009-03
Mounting and
operating instructions
automatic zero function is active
1
, Q
, H, OK, T and Z
1
2