EMERGENCY OPERATION

8
6. EMERGENCY OPERATION

6.1. OPERATION AND FUNCTION

In case that the unit is required to be operated when the
wireless remote control switch is out of battery and can not
function, etc., the unit can be operated by the emergency
operation switch.
NOTE:
The unit will operate at the following setting.
Automatic COOL/HEAT Operation
Temperature: 25 o C
Fan Speed: High
Swing Louver: Horizontal
Step 1
Press the emergency operation switch by using a small
bar or things like that.
Timer Filter/Defrost/Run
6.2. ALARM CODE INDICATION
In case that some trouble occures,
"RUN" (red lamp) blinks (0.5 second ON / 0.5 second
OFF)
Alarm code indicates the blinking times of
"TIMER"(green lamp) and "FILTER / DEFROST"
("Yellow Lamp") as shown below.
"TIMER"(green lamp): The blinking is shown at the 2
digit of Alarm Code.
"FILTER / DEFROST" (Yellow lamp): The blinking is
st
shown at the 1
Emergency
operation
nd
.
Step 2
During emergency operation, if pressing the emergency
operation switch again, the unit will be stopped.
CAUTION:
Do not press the emergency operation switch by
using metals such as a pen or a needle.It will cause a
failure.
(Exemple)

Alarm
"FILTER/DEFROST" (Yellow Lamp)
"TIMER" (Green Lamp)
"TIMER" (green lamp) blinks 3 times (0.5 second
ON/0.5 second OFF)
"FILTER/DEFROST" (yellow lamp) blinks 5 times (0.5
second OFF)
It is continued until Alarm Reset.