Herunterladen Inhalt Inhalt Diese Seite drucken

Mettler Toledo BPA224 Bedienungsanleitung Seite 11

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 18
Menu block
Settings
S4
0
1
2
3
4
5
6
7
S5
g
kg
lb
oz
S6
0
1
2
3
DSP (S7)
On
Off
S8
Off
On
S9
Off
On
S10
Off
On
S11
On
Off
S12
On
Off
BAT
CH
D
GEO
0 ... 31
CAL
No
Yes
Except where the factory settings are shown bold, the factory setting depends on the country in which the balance was purchased, on the model of
the balance, or on the respective weights and measures law.
Only the menu blocks shown above with a gray background are available in the user menu; the other menu blocks are only accessible in service mode.
Explanation
Adaptation to the environmental conditions (filter)
Very stable environmental conditions, weak filtering of the weighing signal
Normal environmental conditions, average filtering of the weighing signal
Unstable environmental conditions, stronger filtering of the weighing signal
Very unstable environmental conditions, very strong filtering of the weighing signal
As for setting 0, but with slower updating of the display value
As for setting 1, but with slower updating of the display value
As for setting 2, but with slower updating of the display value
As for setting 3, but with slower updating of the display value.
Weighing unit
Gram
Kilogram (only available if the region is set to "EU" (Europe), see menu block "CTY")
Pound (only available if the region is set to "GE" (USA), see menu block "CTY")
Ounce (only available if the region is set to "GE" (USA), see menu block "CTY")
Brightness of the display
Very bright
Bright
Dark
Very dark
Type of display
Weight value is only displayed when stable
Weight value is displayed continuously, irrespective of whether it is stable
Resolution of the scale (only available in the user menu when "S9" = "On")
3000d
6000d/7500d (depending on the capacity of the scale)
Access to menu item S8 from the user menu
Menu item S8 is not available in the user menu (S8 is only accessible in service mode)
Menu item S8 is available in the user menu
Extended display
Normal weight display depending on the resolution of the balance (see menu item S8)
Only for tests: Display in d (max. scale capacity = 30,000d), keys a and b disabled
Display of negative weight values
Display of negative weight values disabled (display shows "oooooo"), taring not possible
Display of negative weight values enabled, taring possible (not allowed for certified balances)
Speed of display when removing the load
Return to zero by display is fast
Display returns to zero at normal speed
Type of internal power supply
Rechargeable storage battery
Commercial battery size "D" (IEC "R20")
Geo adjustment value (adaptation to local gravitational conditions, see table in Chapter 5)
Factory setting according to region
Scale adjustment (calibration)
Do not perform adjustment
Perform adjustment (see description in Chapter 4.3)
METTLER TOLEDO BPA224 Scales
11

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis