Herunterladen Inhalt Inhalt Diese Seite drucken

Top View; Side View - Velleman HAA52N Bedienungsanleitung

Pir-detektor
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

5. Coverage pattern
6. PCB description
a. Connection Terminal Description
ALARM
This is the alarm relay output contact of the detector. It is selectable as NC or
NO via the alarm jumper to match the requirements of the protection zone.
DC12V
Connect the positive (+) side to an 8V ~ 16V DC power source, usually from the
alarm control panel. Connect the negative (-) side to the common grounding
point of the control panel.
TAMP NC
If a tamper switch is required, connect these terminals to a 24-hour NC
protection zone in the alarm control panel. The tamper switch contact is closed
with the detector's front cover secured on the box. The opening of the front
cover at any time will make the contact open and send an immediate alarm
signal to the control panel.
01 (10/10/2008)
HAA52N

Top view

Side view

1. PCB fixing screw
2. Alarm output jumper
3. Pulse mode jumper
4. LED on/off jumper
5. Test/alarm indicator
6. Pyro sensor (do not touch!)
7. Connection terminal block
8. Tamper switch
4

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis