Faults, troubleshooting
A regular and careful cleaning and maintenance schedule is required to ensure trouble-free
operation. The transformer should be disconnected from the socket during troubleshooting
measures. Remove the mains plug!
If the wire does not heat up, check the 230 V power supply. Check or replace the transformer fuse (art. no.
570004). If this does not resolve the malfunction, contact the STORCH service department or one of the
STORCH service centres in your area. Do not attempt to repair the transformer yourself and do not replace
it with a type not approved by STORCH. Other malfunctions that require the device to be repaired may only
be performed by qualified STORCH personnel or one of the authorised STORCH service centres.

Guarantee, warranty, liability

We guarantee the flawless operation of the device under the condition that it is duly operated and
maintained. The warranty expires 1 year after the date of purchase (billing date). It is restricted to material
and manufacturing defects. Additional claims and replacement of wear and tear parts (e.g. cutting wire art.
no. 57 00 47, fuses art. no. 57 00 04) are excluded. Any variations from the intended use will result in
expiration of the warranty.
The device must be deployed and operated in accordance with the conditions specified in this manual. We
shall not assume any liability or warranty for damages resulting from non-compliance or improper handling.

Personnel qualification

The device should only be assembled, commissioned, operated, maintained and cleaned by
those persons who are authorised, qualified and trained to do so.
Spare parts, consumables
All of the device components are available from STORCH and its distribution partners. We recommend
that you keep sufficient quantities of the original cutting wire (d=0.7 mm) (art. no. 57 00 47) and fine wire
fuses 8A (art. no. 57 00 04) in stock.
Transport protection
Upon delivery of the ProCut multi, the cutting bow is secured with the blue tension strap for
transport (see figure below). Please note ensure that the cutting bow must be secured prior to
any transport in the transport case, in the box, or in this manner in case it is repositioned on
the construction site!