Verfügbare Sprachen

Protokollmeldung: The external Smart Array controller located in the MSA
chassis labeled as <chassis label> has reported that due to an
unrecoverable read error, the recovery of logical drive <logical drive
number> was aborted while rebuilding a physical drive. The physical drive
which was being rebuilt is located in bay <bay number 1> of the MSA
chassis. The physical drive that reported the read error is located in
bay <bay number 2> of the MSA chassis.
The external Smart Array controller is attached to the host side Smart
Array controller <controller name / slot information>.
Meldungs-ID: 24716
Schweregrad: Warnung
Protokollmeldung: The external Smart Array controller located in the MSA
chassis labeled as <chassis label> has reported that the recovery of
logical drive <logical drive number> was aborted while rebuilding due to
an unrecoverable write error. Physical drive number <physical drive
number 1> was the replacement drive being rebuilt before the write error
occurred, while physical drive number <physical drive number 2> is the
error drive which reported the write error.
The external Smart Array controller is attached to the host side Smart
Array controller <controller name / slot information>.
Meldungs-ID: 24717
Schweregrad: Warnung
Protokollmeldung: The external Smart Array controller located in the MSA
chassis labeled as <chassis label> has reported that due to an
unrecoverable write error, the recovery of logical drive <logical drive
number> was aborted while rebuilding a physical drive. The physical drive
which was being rebuilt is located in bay <bay number 1> of the MSA
chassis. The physical drive that reported the write error is located in
bay <bay number 2> of the MSA chassis.
The external Smart Array controller is attached to the host side Smart
Array controller <controller name / slot information>.
Meldungs-ID: 24718
Schweregrad: Fehler
Protokollmeldung: The external Smart Array controller located in the MSA
chassis labeled as <chassis label> has reported that logical drive
<logical drive number> returned a fatal error during a read/write request
from/to the volume.
Logical block address <lba number>, block count <block count> and command
<command number> were taken from the failed logical I/O request.
The external Smart Array controller is also reporting that the last
physical drive to report a fatal error condition(associated with this
specific logical request), is located on bus <bus number> and ID <ID
number>.
The external Smart Array controller is attached to the host side Smart
Array controller <controller name / slot information>.
DEWW
Smart Array-Meldungen im Windows-Ereignisprotokoll 139

Werbung

loading