OPERATION
After connecting the device to the mains it is ready for operation. The display indicates the last operating
mode. The operating modes can be selected by means of the display and the control buttons. All settings
remain stored even if the device is disconnected from the mains. The device can be operated in stand-alone
mode via the control board or in DMX-controlled mode via any commercial DMX controller.
Control Board
The Control Board offers several features: you can simply set the starting address, run the pre-programmed
program or select a DMX channel mode.
Browse through the menu by pressing Menu. Press Enter in order to select the desired menu. You can
change the selection by pressing Up or Down. Press Enter in order to confirm. You can leave every mode by
pressing Menu. The functions provided are listed in the following sections.
Menu
Sub menu
R.000
G.000
B.000
STAT
W.000
Y.000
U.000
ST.00
AT.01
AUTO
PR.01
MOD1
SOUD
MOD2
DMX
RUN
SLAV
DMX
d001-512
STAG
ARC.1
AR1.d
PERS
ARC.2
AR2.d
AR2.S
HSV.
TEMP
CURR
EDIT
PR.01-
PR.10
UPLD
SET
REST
000-255
000-255
000-255
000-255
000-255
000-255
00-20
01-10
01-10
R.000 (000-255)
Red
G.000 (000-255)
Green
B.000 (000-255)
Blue
W.000 (000-255)
White
SC.01-
Y.000 (000-255)
SC.30
Amber
U.000 (000-255)
UV
ST.00 (00-20)
Strobe
T.000
Duration of the scene
F.000
Fade time of the scene
Description
Dimmer intensity of LED colors
Strobe effect 0 – 20 (increasing)
Automatic programs
User defined automatic programs (s. EDIT)
Sound controlled program (color change)
Sound controlled program (strobe)
DMX controlled mode
Slave mode
DMX address setting
Default setting:001
Setting DMX channel mode
STAG:14 DMX channels
ARC.1:5 DMX channels
AR1.d:6 DMX channels
ARC.2:8 DMX channels
AR2.d:9 DMX channels
AR2.S:10 DMX channels
HSV.:3 DMX channels
Temperature inside of the device
With this function, you can edit the user defined
automatic programs (PR.01-PR.10), which can be
called up under AUTO.
Each program (PR) with 30 scenes (SC.01-SC.30),
each scene with 9 steps (R/G/B/W/Y/U/ST/T/F).
Transfer of the user defined automatic programs
(PR.01-PR.10) to another device (password is up-
down-up-down-enter)
Reset (password: Up-Down-Up-Down-Enter)
21/28