Connection with the mains
Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
OPERATION
After you connected the effect to the mains, the LED TSL-600 Scan COB starts running. During the Reset,
the motors are trimmed and the device is ready for use afterwards.
Turn the objective-lens for adjusting the focus in order to obtain a sharp projection.
Stand Alone operation
In the Stand Alone mode, the LED TSL-600 Scan COB can be used without controller. You can do without a
controller as the LED TSL-600 Scan COB features a built-in microphone, which provides automatic sound
control.
Disconnect the LED TSL-600 Scan COB from the controller and select the desired "Master Mode".
Master/Slave-operation
The master/slave-operation enables that several devices can be synchronized and controlled by one master-
device.
On the rear panel of the LED TSL-600 Scan COB you can find an XLR-jack (DMX Out) and an XLR-plug
(DMX In), which can be used for connecting several devices.
Choose the device which is to control the effects. This device then works as master device and controls all
other slave devices, which are to be connected to the master device via a DMX cable. Connect the DMX
OUT jack with the DMX IN plug of the next device.
Set the desired Master-mode for the master-device. Set the respective Slave-mode for all slave-devices.
Please refer to the instructions under Control Board.
International
L
N
20/24
00071947.DOC, Version 1.0