2.3 Models and characteristics
CODE
DESCRIPTION
for sectional doors up to 10 mq with motor 24 Vdc and
VIP7U/(VIP7UL)
central with integrated receiver
for sectional doors up to 10 mq with motor 24 Vdc and
VIP7/(VIP7L)
central with integrated receiver
for sectional doors up to 13 mq with motor 24 Vdc and
VIP10U/(VIP10UL)
central with integrated receiver
for sectional doors up to 13 mq with motor 24 Vdc and
VIP10/(VIP10L)
central with integrated receiver
for sectional doors up to 16 mq with motor 24 Vdc and
VIP104/(VIP104L)
central with integrated receiver
TECHNICAL DATA
Speed
Force
Working cycle
Stroke
Power
Absorption at 230 Vac (120 Vac)
Absorption of 24 Vdc motor
Consumption power
Integrated lights
Flashing light
External courtesy light
Accessory power supply output
Power line 1 fuse
Max. number of transmitters
storage FIX CODE
Max. number of transmitters
storage ROLLING CODE
Protection degree
Dimensions (L - P - H)
Weight
Working temperature
Max door size
Max door weight
2.4 Technical specifications
Suggested use and model - Guide and available dimensions
Model
Voltage (V)
VIP7U/
190-240
(VIP7UL)
(110 - 130)
VIP7/
190-240
(VIP7L)
(110 - 130)
VIP10U/
190-240
(VIP10UL)
(110 - 130)
VIP10/
190-240
VIP10L)
(110 - 130)
VIP104/
190-240
(VIP104L)
(110 - 130)
Data may change depending on the door friction and balance, and the tipe of guide used.
155
VIP7U/VIP7
VIP10U/VIP10
(VIP7UL/VIP7L)
(VIP10UL/VIP10L)
12 cm/s
12 cm/s
700 N
1000 N
60 %
60 %
2,8 m
2,8 m
230 Vac (120 Vac) 230 Vac (120 Vac) 230 Vac (120 Vac)
0,5 A (1 A)
0,7 A (1,4 A)
4,16 A
6,66 A
100 W
160 W
yes
yes
15 W MAX
15 W MAX
10 W MAX
10 W MAX
250mA (24 Vdc)
250mA (24 Vdc)
2.5AT slow-acting 2.5AT slow-acting 2.5AT slow-acting
20
20
20
20
IP 43
IP 43
200-370-155 mm
200-370-155 mm
13 Kg
13,5 Kg
-20° + 55° °C
20° + 55° °C
10 m
13 m
2
90 Kg
130 Kg
Door
Total length
surface (m
)
2
3320 mm (1x3,3m)
<=10
3320 mm (3x1,1m)
<=10
3320 mm (1x3,3m)
<=13
3320 mm (3x1,1m)
<=13
<=16
4000 mm (1x4m)
35
FORCE
700N
700N
1000N
1000N
1000N
VIP104
(VIP104L)
12 cm/s
1000 N
60 %
3,5 m
0,7 A (1,4 A)
6,66 A
160 W
yes
15 W MAX
10 W MAX
250mA (24 Vdc)
20
20
IP 43
200-370-155 mm
16 Kg
-20° + 55° °C
16 m
2
2
130 Kg
Travel of the
Height of the door
guide
when opening
2700 mm
<2700 mm
2700 mm
<2700 mm
2700 mm
<2700 mm
2700 mm
<2700 mm
3400 mm
<3400 mm
370
200
GUIDE
pre-assembled chain rail 3320 mm in single
piece
chain rail 3320 mm into three pieces with fast
joints
pre-assembled chain rail 3320 mm in single
piece
chain rail 3320 mm into three pieces with fast
joints
pre-assembled chain rail 4000 mm in single
piece
LIMITS OF USAGE
sectional
up and over
VIP7U/VIP7/(VIP7UL/VIP7L)
H max=2,7m
H max=3m
m² max=10m²
m² max=9m²
VIP10U/VIP10/(VIP10UL/VIP10L)
H max=2,7m
H max=3m
m² max=13m²
m² max=14m²
VIP104 (VIP104L)
H max=3,4m
H max=3,4m
m² max=16m²
m² max=14m²
Ambient temperature
difference (°C)
-20+55
-20+55
-20+55
-20+55
-20+55
3080
70
EN
non projecting
up and over
H max=2,5m
m² max=9m²
H max=2,5m
m² max=14m²
H max=3,2m
m² max=14m²
21