Using The Battery Monitor - Dometic COOLFREEZE CDF16 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 17
CoolFreeze CDF16
6.4

Using the battery monitor

If the cooler is operated when the vehicle ignition is switched off, the cooler switches
off automatically as soon as the supply voltage falls below a set level. The cooler will
switch back on once the battery has been recharged to the restart voltage level.
A
NOTICE! Danger of damage!
When switched off by the battery monitor, the battery will no longer be
fully charged. Avoid starting repeatedly or operating current consumers
without longer charging phases. Ensure that the battery is recharged.
In "HIGH" mode, the battery monitor responds faster than at the levels "LOW" and
"MED" (see the following table).
Battery monitor mode
Switch-off voltage at 12 V
Restartvoltage at 12 V
Switch-off voltage at 24 V
Restart voltage at 24 V
I
NOTE
When the cooler is supplied by the starter battery, select the battery
monitor mode "HIGH". If the cooler is connected to a supply battery,
the battery monitor mode "LOW" will suffice.
➤ Switch on the cooler.
➤ Press the "SET" button three times.
➤ Use the "UP +" and "DOWN –" buttons to select the battery monitor mode.
✓ The selected mode then appears in the display for a few seconds. The display
flashes several times before it returns to the current temperature.
EN
LOW
10,6 V ± 0,3 V
11,4 V ± 0,3 V
11,6 V ± 0,3 V
12,2 V ± 0,3 V
22,0 V ± 0,3 V
24,1 V ± 0,3 V
23,5 V ± 0,3 V
25,3 V ± 0,3 V
Operation
MED
HIGH
11,8 V ± 0,3 V
12,6 V ± 0,3 V
24,6 V ± 0,3 V
26,2 V ± 0,3 V