9 - Troubleshooting:
Problem
The automatic gate system does not work
You cannot save the remote controls
As soon as the gate starts it stops and reverses
During slowdown, the gate stops and reverses
Movement of one of the 2 motors is reversed
During calibration the motor M1 starts and stops
after 1 second
With the electrical lock the motor 1 is not able to
start opening or does not close completely
10 - Mechanical installation:
For correct installation secure the box in a safe place where it is protected
from the weather. To secure the box in the wall you have to remove the 4
plastic screws and open the cover.
Overall dimensions of control unit:
26
Cause
No mains supply
Blown fuses
Control and safety inputs not working
Safety devices open
Batteries of the remote control discharged
Remote control not compatible with the first one
saved
Reached memory saturation
Motor torque not sufficient
Slowdown speed too low
Wrong wiring
Encoder 1 wiring reversed with encoder 2
Electrical lock does not reset
Solution
Check the power line switch
Replace the fuses with others of the same value
Check the diagnosis LEDS (stop, STPA and photo
must be on)
Check the diagnosis LEDS (stop, STPA and photo
must be on)
Replace the batteries
The first saved remote control configures the
control panel to save only rolling-code remote
controls or only dip-switch remote controls.
Delete at least one remote control or add an
external receiver (maximum capacity 200 remote
controls)
Increase the force via trimmer TR1 for motor M1
and TR2 for M2
Increase the value of trimmer TR3
Check the motor wiring
(1= opens M1/2= closes M1/3= opens M2/ 4=
closes M2)
Check the encoder wiring
Set dip switch 2-1 on (electric lock connection
disconnection function)
EN