24. Automatic error diagnostics
In the case of error, error codes are shown in displays.
There are 2 types of errors:
- Error messages are deleted automatically (short-term errors)
- An error must be deleted by switching the welder on and off again (major fault / defect)
Error number
Error description and possible diagnosis
E0.0
VOLTAGE SUPPLY ERROR
This error can only occur when switching on the unit, not during normal operation of the
welding unit.
This error is shown only on the display, but not saved in the error memory.
Deleting an error by switching the unit on and off again.
E0.1
REDUCED VOLTAGE AND OVERVOLTAGE
Error message deletes automatically
E0.2
OVERVOLTAGE
Error message deletes automatically
E0.3
REDUCED VOLTAGE
Error message deletes automatically
E0.4
OVERLOAD CURRENT
Error message deletes automatically
E0.5
REMOTE CONTROL
Lack of remote control power supply
Delete this error by switching the unit off and on again.
E0.6
WATER COOLING UNIT
The machine wait for a signal from the cooling unit.
- Check the hoses
- Contact JÄCKLE customer service
Delete this error by switching the unit off and on again.
E0.7
WF MOTOR ERROR
Motor in the wire feed housing not functioning.
- Check motor
- Contact JÄCKLE customer service
Delete this error by switching the unit off and on again.
E0.8
WIRE FEEDER MISSING
The machine waits for a signal from the wire feeder.
- Check intermediate hose assembly
- Contact JÄCKLE customer service
Delete this error by switching the unit off and on again.
E0.9
CAN ERROR
The CAN communication between the machine and the wire feeder has been
interrupted.
- Check intermediate hose assembly
- Contact JÄCKLE customer service
Delete this error by switching the unit off and on again.
T°C
Excessive temperatures
The machine has switched off due to overheating.
Let the machine rest with the fan running until the message disappears.
Error message deletes automatically
H2o
COOLING UNIT PRESSURE
The cooling unit is recognised by the welder but the pressure switch is not functioning.
- Check the water level and fill if required.
- Check the lines
- Check to see if the pressure switch is functioning
Delete this error by switching the unit off and on again.
E1.0
CONFIGURATION FILE IS MISSING (configuration file is missing)
Internal error in the software
- Contact JÄCKLE customer service
This error is shown only on the display, but not saved in the error memory.
Delete this error by switching the unit off and on again.
Operating manual
ProPuls 330,400,500
Page 60