3. Technical data
3.4 Model PGT23.100, PGT23.160
Working pressure
- Steady
- Fluctuating
- Transient
Temperature influence
IP protection class
- Housing
- With liquid filling
Permissible tempera-
tures
- Ambient
- Medium
Further technical data see data sheet PV 12.04
3.5 Model PGT43.100, PGT43.160
Working pressure
- Steady
- Fluctuating
- Transient
Temperature influence
IP protection class
- Housing
- With liquid filling
Permissible tempera-
tures
- Ambient
- Medium
Further technical data see data sheet PV 14.03
3.6 Model PGT43HP.100, PGT43HP.160
Working pressure
- Steady
- Fluctuating
- Overload capability
Temperature influence
IP protection class
- Housing
- With liquid filling
Permissible tempera-
tures
- Ambient
- Medium
Further technical data see data sheet PV 14.07
WIKA Operating Instructions intelliGAUGE family
Full scale range
0.9 x full scale range
1.3 x full scale range
max. ± 0.4 % of full scale range/10 K (when the temperature of the
measuring system deviates from +20 °C reference temperature)
IP54 per EN/IEC 60529
IP65
filled/unfilled -40 ... +60 °C
maximum +100 °C
Full scale range
0.9 x full scale range
5 x full scale range, however max. 40 bar
max. ± 0.8 % of full scale range/10 K (when the temperature of the
measuring system deviates from +20 °C reference temperature)
IP54 per EN/IEC 60529
IP65
filled/unfilled -20 ... +60 °C
maximum +100 °C
Full scale range
0.9 x full scale range
40, 100 and 400 bar
max. ± 0.8 % of full scale range/10 K (when the temperature of the
measuring system deviates from +20 °C reference temperature)
IP54 per EN/IEC 60529
IP65
filled/unfilled -20 ... +60 °C
maximum +100 °C