Chauvin Arnoux F 21 Bedienungsanleitung Seite 24

Oberwellen - analysezange
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 29
AC VOLTAGES
Digital display
V RMS or PEAK
Measurement
Automatic
extent of the
display
Manual
Resolution
- Response time : every 500ms
Analogue display
- Range 0 to 60V, resolution : 2V
Range 0 to 600V, resolution : 20V
- Response time : every 100ms
Accuracy on RMS voltage
V RMS
Specified measu-
0.50V to 99.99V
rement range
Accuracy
1.5% R + 4 counts
- Input impedance : 1MΩ
- Frequency range : from 15Hz to 10kHz
- Additional error with the crest factor CF :
. CF from 1.5 to 3 : +1.5%
. CF from 3 to 5 : +2.5%
. CF from 5 to 7 : +5%
Range overload
. Automatic mode - Above 600.0V RMS, the warning signal is emitted to indicate that
the voltage measured is outside the specified range.
. Manual mode - Above 99.99V on the 1st range the display indicates "OL" and the
warning signal is emitted.
. Automatic and manual modes - Above 999.9V the display indicates "OL" and the
warning signal is emitted.
1st range
2nd range
0.05V to 66.00V
60.0V to 999.9V
0.05V to 99.99V
0.1V to 999.9V
10mV
100mV
100.0 to 399.9V
400.0V to 600.0V
1.5% R
41
Accuracy on PEAK voltage for 1ms
V PEAK
Specified measu-
0.40V to 99.99V
rement range
Accuracy
3%R + 30 counts
- Frequency range : from 10Hz to 500Hz
Range overload
. Automatic mode - Above 850V PEAK, the warning signal is emitted.
. Manual mode - Above 99.99 V on the 1st range the display indicates "OL" and the
warning signal is emitted.
. Automatic and manual modes - Above 999.9V the display indicates "OL" and the
warning signal is emitted.
Permitted permanent overload : 1.5kV PEAK
FREQUENCIES
Hz
1st range
Measurement extent
0.5Hz to 999.9Hz
Resolution
0.1Hz
Accuracy
0.1% R + 1 count
NB :
- Range selection is always automatic.
- Pressing the RANGE button sets the triggering threshold.
- Below 0.5Hz or if the level of detection is insufficient, the display indicates 0.0Hz.
Triggering threshold
- Automatic : - on voltage from 1V
- on current from 1A
- Manual (RANGE): 10% approx of the voltage or current range selected.
Permitted overload and warning signal : idem Currents and Voltages
100.0V to 999.9V
3% R
2nd range
1000Hz to 9999Hz
1Hz
0.2%R + 1 count
42