deutsch (Originalsprache)
Bestimmung und Gebrauch
Die Positionsschalter der Reihe Ex 14 / ExM 14 entsprechen den Euro-
päischen Normen für den Explosionsschutz EN 60079-0, EN 60079-1
und EN 60079-31 und sind daher für den Einsatz in explosionsgefähr-
deten Bereichen der Zone 1 und 2 sowie Zone 21 und 22 nach EN
60079-14 und EN 61241-14 vorgesehen. Die Anforderungen der EN
61241-14 z. B. in Bezug auf Staubablagerungen und Temperaturgren-
zen sind zu erfüllen. Die Positionsschalter mit Sicherheitsfunktion Ex
14 dienen dem Einsatz in Sicherheitsstromkreisen zur Stellungsüber-
wachung beweglicher Schutzeinrichtungen nach EN 1088 und IEC
60947-5-1.
Befestigung / Anschluss
Den Positionsschalter auf einer ebene Fläche befestigen. Bei der Mon-
tage ist darauf zu achten, dass ein Verschieben des Positionsschalters
mit Sicherheitsfunktion auch im Fehlerfall verhindert wird. Den Schal-
ter gegen unbefugtes Lösen sichern, z. B. mit Einweg-Sicherheits-
schrauben. Bei der Montage des Sicherheitsschalters sind die Anfor-
derungen nach DIN EN 1088, insbesondere die Punkte 5.2 und 5.7, zu
berücksichtigen! Bitte beachten Sie auch die Hinweise der Normen
EN 292 und EN 953.
Hinweise
Der elektrische Anschluss darf nur von autorisiertem Fachpersonal
durchgeführt werden. Der Schalter darf nicht als mechanischer An-
schlag verwendet werden. Die Gebrauchslage ist beliebig. Die Positi-
onsschalter sind so zu montieren, dass das Gehäuse vor mechani-
scher Belastung bzw. Beschädigung hinreichend geschützt ist. Die
Anschlussleitung dieses Schalters muss fest und so verlegt werden,
dass sie vor mechanischer Beschädigung hinreichend geschützt ist
(Zulassungsbedingung X). Umbauten und Veränderungen am Schal-
ter, die den Explosionsschutz beeinträchtigen, sind nicht gestattet.
Ferner gilt für das Errichten von elektrischen Betriebsmitteln in explo-
sionsgefährdeten Bereichen die EN 60079-14 und EN 61241-14. Zu be-
achten ist ferner die ATEX-Prüfbescheinigung und die darin enthalte-
nen besonderen Bedingungen. Für die Verschaltung des Schalters in
das Gesamtsystem muss die in der Risikoanalyse festgelegte Steue-
rungskategorie durchgehend eingehalten werden. Hierzu ist auch eine
Validierung nach EN ISO 13849-2 bzw. nach DIN EN 62061 erforderlich.
Desweiteren kann der Performance Level bzw. SIL CL Level durch
Verkettung von mehreren Sicherheitsbauteilen und anderen sicher-
heitsgerichteten Geräten, z. B. Reihenschaltung von Schaltern, nied-
riger ausfallen als die Einzellevel. Es liegt im Verantwortungsbereich
des Herstellers einer Anlage oder Maschine, die korrekte Gesamt-
funktion sicherzustellen. Änderungen, die dem technischen Fortschritt
dienen, vorbehalten. steute übernimmt keine Haftung für Empfehlun-
gen, die durch diese Beschreibung gegeben oder impliziert werden.
Aufgrund dieser Beschreibung können keine neuen, über die allge-
meinen steute-Lieferbedingungen hinausgehenden, Garantie-Gewähr-
leistungs- oder Haftungsansprüche abgeleitet werden.
Wartung
Bei rauen Betriebsbedingungen empfehlen wir eine regelmäßige
Wartung mit folgenden Schritten:
1. Prüfen des Betätigers auf Leichtgängigkeit
2. Entfernen von Schmutzresten
3. Nachschmieren der Wellen oder Bolzen
4. Prüfen der Leitungseinführung und -anschlüsse
English
Destination and use
The position switches of series Ex 14 / ExM 14 comply with the Euro-
pean standards for explosion protection EN 60079-0, EN 60079-1 and
EN 60079-31 and therefore are designed for the explosive areas of
zone 1 and 2 as well as zone 21 and 22 as per DIN EN 60079-14 and EN
61241-14. The requirements of EN 61241-14 e. g. regarding dust depo-
sition and temperature limits must be met. The position switch Ex 14
with safety function is used in safety circuits to monitor the position of
mobile safety guards to EN 1088 and EN 60947-5-1.
Mounting / Wiring
The position switch should be mounted on an even surface. Please
ensure that, even in case of failure, the position switch cannot be
moved from its position. For protection against manipulation use one-
way safety screws which are optional available. Please adjust screws
at both sides with the same number of turns with a screwdriver. When
mounting the safety switch please observe the requirements of DIN
EN 1088, especially paragraph 5.2 and 5.7! Please observe the in-
structions in the standards EN 292 and EN 953.
Notices
The electrical connection may only be carried out by authorised per-
sonnel. Do not use the sensor as mechanical endstop. Any mounting
position is possible. The position switches must be mounted in such a
way that the enclosure is protected against mechanical load and da-
mage. The connection cable has to be fixed and laid in a way that it is
protected against mechanical damages (approval condition X). Recon-
struction and alterations at the switch - which might affect the explosi-
on protection - are not allowed. Furthermore EN 60079-14 and EN
61241-14 have to be applied for the installation of electrical equipment
in explosive areas. Moreover the ATEX test certificate and the enclosed
special conditions have to be observed. The described products have
been developed in order to assume safety functions as a part of an
entire plant or machine. A complete safety system normally covers
sensors, monitoring modules, indicator switches and concepts for safe
disconnection. For the integration of the safety switch in the entire sy-
stem, the control category determined in the risk assessment must be
strictly observed and respected. Therefore a validation according to EN
ISO 13849-2 or DIN EN 62061. Furthermore the Performance Level
and SIL CL can be lower because of the combination of several safety
components and other safety-related devices, e.g. by serial connec-
tion of sensors than the single level. The responsibility taken by the
manufacturer of a plant or machine implies to secure the correct ge-
neral function. Subject to technical modifications. Moreover steute
does not assume any liability for recommendations made or implied by
this description. From this description new claims for guarantee, war-
ranty or liability cannot be derived beyond the general terms and con-
ditions of delivery.

Werbung

loading

Inhaltszusammenfassung für steute Ex 14

  • Seite 1 Destination and use zen sind zu erfüllen. Die Positionsschalter mit Sicherheitsfunktion Ex The position switches of series Ex 14 / ExM 14 comply with the Euro- 14 dienen dem Einsatz in Sicherheitsstromkreisen zur Stellungsüber- pean standards for explosion protection EN 60079-0, EN 60079-1 and...
  • Seite 2 être respectées. L'interrupteur de positi- normative Europee per la protezione da esplosioni EN 60079-0, EN on à fonction de sécurité Ex 14 est prévu pour l’utilisation dans les cir- 60079-1 e EN 60079-31 e sono quindi adatti all’impiego in aree con pe- cuits de sécurité...
  • Seite 3 »Condições Gerais de Fornecimento«. Definições e uso Os fins de curso da linha Ex 14 / ExM 14 atendem plenamente as Manutenção exigências de proteção contra incêndios nos termos das normas euro- Quando os equipamentos estiverem instalados em condições ambien-...
  • Seite 4 Ex 14 / ExM 14 Montage- und Anschlussanleitung / Positionsschalter Mounting and wiring instructions / Position switch Instructions de montage et de câblage / Interrupteur de position Istruzioni di montaggio e di collegamento / Interruttori di posizione Instruções de montagem e instalação / Interruptores de posicionamento Инструкции...
  • Seite 5 Montaggio corretto Temperaturklasse Ex 14: T6 / T5; ExM 14: T6 Observações de montagem Umgebungstemperatur Ex 14: T6 = -20 °C bis +65 °C, T5 = -20 °C bis Инструкции по монтажу +75 °C mit spez. temperaturbeständiger Anschlussleitung; ExM 14: T6 = -20 °C bis +60 °C...
  • Seite 6 EN 60079-0, EN 60079-1, EN 60079-31, Classe di temperatura Ex 14: T6 / T5; ExM 14: T6 EN 60947-5-1; EN ISO 13849-1 Temperatura circostante Ex 14: T6 = -20 °C fino a +65 °C, T5 = -20 °C Boîtier thermoplastique renforcé de fibres de verre, fino a +75 °C con cavo speciale resistente ad...
  • Seite 7 EN 60947-5-1; EN ISO 13849-1 Привод соответствует задачам безопасности Корпус армированный стекловолокном, ударо- прочный термопластик, не поддержива- Ex 14 … W, F, KU, WKU, FKU, VKU, R, WR FR, VR, D, DL ющий горение UL 94-V0, с защитной изоляцией Переключающая плавное или cкачкообразное соединение- * Atex­Zulassung gültig für...
  • Seite 8: Eg-Konformitätserklärung Ec-Declaration Of Conformity

    EC-DECLARATION OF CONFORMITY Im Sinne der EG-Maschinenrichtlinie 2006/42/EG und Explosionsschutzrichtlinie 94/9/EG According to the EC Machinery Directive 2006/42/EC and Explosion Proof Directive 94/9/EC Bezeichnung des Betriebsmittels Ex 14 ... Name of the component Beschreibung des Betriebsmittels Positionsschalter mit Sicherheitsfunktion Description of the component...
  • Seite 9 EG-KONFORMITÄTSERKLÄRUNG EC-DECLARATION OF CONFORMITY Im Sinne der EG-Niederspannungsrichtlinie 06/95/EG und Explosionsschutzrichtlinie 94/9/EG According to the EC Low Voltage Directive 06/95/EC and Explosion Proof Directive 94/9/EC Bezeichnung des Betriebsmittels ExM 14 ..., ExM 14 … 1Ö/1S Name of the component Beschreibung des Betriebsmittels Positionsschalter Description of the component position switch...
  • Seite 10 Zusatzinformation zu Montage- und Anschlussanleitungen Additional information on mounting and wiring instructions Information complémentaire aux instructions de montage et de câblage Ulteriori informazioni sulle istruzioni di collegamento e montaggio Informação adicional para as instruções de montagem Дополнительная информация по монтажу и инструкциям по подключению Auf Anfrage erhalten Sie diese Montage- und Anschlussanleitung auch При...

Diese Anleitung auch für:

Exm 14