4
Factory mode and trouble shooting
4.1
Factory mode
Back to factory mode
•
Connect the setting ca�le.
•
Push �oth �uttons (Up & Down) at the same time for 15 seconds (if dou�le push �utton used) or press on
WT �utton of setting ca�le for 15 seconds.
•
Motor turns �riefly two times.
•
The current position of the venetian �lind is stored as lower end limit.
•
The upper end limit is 120 motor rotations a�ove the lower end limit.
4.2
Trouble shooting
Motor does not turn
Check:
•
The wiring of the motor.
•
If the motor is overheated (wait for cool down of the motor).
•
If the appropriate ca�les are used.
© 2009 Somfy SAS. All rights reserved. 12/2009
27