Herunterladen Inhalt Inhalt Diese Seite drucken

Before Initial Operation; Temperature Setting; Operation Parameters - Schneider SCB300V2B Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4.1 Before initial operation

1. Clean the appliance thoroughly. Be very careful especially inside the appliance.
2. After having installed the appliance wait 4-6 hours before you connect it
to the mains.
3. • Positions 1 and 2 correspond to a lower cooling power.
• Positions 3 and 4 correspond to a normal cooling power.
• Position 5-7 generates the appliance maximum cooling power.
In normal usage conditions you are advised to select a positions 3 or 4 for proper
conservation of foodstuff in the appliance.
4. Afterwards operate the appliance after 24 hours for the first time.
5. The temperature of the freezer should reach -18
the exact temperature of the cooling and freezer compartments using a suitable
thermometer
.
5
WARNING! THE THERMOSTAT CONTROLS THE COMPRESSOR
ONLY. You must unplug the appliance to disconnect it from the mains.

4.2 Temperature setting

1
Warmest setting
3/4
Recommended setting for daily use at an average ambient
temperature of 16°C to 38°C.
7
Coldest setting

4.3 Operation parameters

1. The appliance can only reach the relevant temperatures when:
a. the a ambient temperature meets the climatic class.
b. the doors close properly.
Not included in delivery
5
0
C or colder. You can check
27

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis