Technical data

Mains voltage
Power input
Working pressure
Nominal pressure
Delivery rate
Max. water inlet pressure
Protection class
Danger!
Sound and vibration
Sound and vibration values were measured in ac-
cordance with EN 60335.
L
sound pressure level
pA
K
uncertainty
pA
L
sound power level
WA
K
uncertainty
WA
Wear ear-muffs.
The impact of noise can cause damage to hearing.
Total vibration values (vector sum of three directions)
determined in accordance with EN 60335.
Vibration emission value a
h
The specified vibration value was established in ac-
cordance with a standardized testing method. It may
change according to how the electric equipment is
used and may exceed the specified value in excep-
tional circumstances.
The specified vibration value can be used to compare
the equipment with other electric power tools.
The specified vibration value can be used for initial
assessment of a harmful effect.
Keep the noise emissions and vibrations to a
minimum.
Only use appliances which are in perfect working
order.
Service and clean the appliance regularly.
Adapt your working style to suit the appliance.
Do not overload the appliance.
Have the appliance serviced whenever necessary.
Switch the appliance off when it is not in use.
Wear protective gloves.
Before putting the machine into opera-
tion
Correctly using the device
The high-pressure cleaner must be set on a level,
stable surface..
It is recommended that you maintain the correct
operating position every time you use the machine
by placing one hand on the pistol and the other on
the lance.
18 І GB
 www.scheppach.com /  service@scheppach.com /  +(49)-08223-4002-99 /  +(49)-08223-4002-58
230-240 V~ / 50 Hz
2400 W
12 MPa
18 MPa
5.5 l/min
0.4 MPa
II
78 dB(A)
3 dB(A)
94 db(A)
3 dB(A)
≤ 2,5 m/s
2
Never direct the water jet toward electrical lines or
the machine itself.
It is normal for the pump to leak a little; this is nec-
essary to avoid damage to the pump when it is at
a standstill.
Never use the equipment in potentially explosive
areas under any circumstances!
The operating temperature must be between +5
and + 50°C.
Do not cover or modify the lance or the spray noz-
zles in any way.
The high-pressure cleaner is designed to be used
with cold or lukewarm water (max. 50°C); higher
temperatures can damage the pump.
Do not use water that is dirty, gritty or contains any
chemical products, as these could impair operation
and shorten the life of the equipment.
Assembly
Device assembly (fig. 4)
Push the handle (1) onto the fastening points at the
top of the device and secure using the two screws
provided (length 20 mm)
Water supply connection (Fig. 2)
Screw the connection for the water supply (10) onto
the device. The connection for the water supply (10)
features a connection for standard hose coupling
systems. Attach the hose coupling of the supply hose
(min. Ø 1/2"/ approx. 13 mm) onto the connection for
the water supply (10) .
Always use an enhanced water hose with an in-
dustry-standard coupling for the water supply. The
length should be at least 6.0 m. (not included in the
scope of delivery)
A backflow prevention device must be installed be-
tween the drinking water and the high-pressure
cleaner! Ask your plumbing expert about this.
Suction from open tanks/containers and natural
bodies of water
Use a special self-suction accessory (not included
with delivery / available from dealer)
With this accessory, the high-pressure cleaner can
take in water 0.5 m above the water level. This can
last about 25 to 50 seconds.
Immerse the accessory's hose completely under wa-
ter to drive the air out of the hose.
Connect the accessory's hose to the high-pressure
cleaner, and make sure that the suction strainer re-
mains under water.
Let the high-pressure cleaner run with the spray gun
removed until the water flows evenly out of the high-
pressure hose.
If no water comes out after 25 to 50 seconds, switch
off and check all connections.
Once the water is flowing, turn off the high-pressure