Parameter name
Display
1.YFCT
1)
2.YAGL
2)
3.YWAY
4.INITA
5.INITM
6.SCUR
7.SDIR
8.SPRA
9.SPRE
10.TSUP
11.TSDO
12.SFCT
13.SL0
14.SL1
3)
usw. bis
(example)
32.SL19
33.SL20
34.DEBA
35.YA
36.YE
37.YNRM
38.YDIR
39.YCLS
40.YCDO
41.YCUP
4)
42.BIN1
4)
43.BIN2
5)
44.AFCT
45.A1
46.A2
5)
47. FCT
48. TIM
49. LIM
50. STRK
51. DCHG
52. ZERO
53. OPEN
54. DEBA
55.PRST
1)
If "turn" is selected, you cannot set 33°
2)
Parameter does not appear if 1.YFCT=turn has been selected
3)
Turning points only appear wih selection 12.SFCT = FrEE
Function
Type of actuator
Rated angle of rotation of feedback
Set transmission ratio selector (7) appropriately
(see view of device)
Stroke range (optional setting)
When used, the value must correspond with
the set of the leverage ratio on the actuator
Driver pin must be set to the value of the actuator
travel or, if this value is not scaled, to the next
larger scale value.
Initialization (automatically)
Initialization (manually)
0 to 20 mA
Current range of setpoint
4 to 20 mA
Setpoint direction
Setpoint for start of split range
Setpoint for end of split range
Setpoint ramp up
Setpoint ramp down
Setpoint function
Equal-percentage 1:25, 1:33, 1:50
Inverse equal-percentage
1:25, 1:33, 1:50
Freely adjustable
Setpoint turning point at 0%
5%
to
95%
100%
Dead zone of controller
Start of manipulated variable limiting
End of manipulated variable limiting
Standardization of
To mech. travel
manipulated variable
Direction of manipulated
variable for display
Tight closing with
manipulated variable
Bottom only
Top and bottom
Value for tight closing, bottom
Value for tight closing, top
Function of BI 1
Only message
Block configuring
Block configuring and manual
Drive valve to position up
Drive valve to position down
Block movement
Function of BI 2
Only message
Drive valve to position up
Drive valve to position down
Block movement
Alarm function
Without
A1=min. A2=max
A1=min. A2=min
A1=max. A2=max
Response threshold of alarm 1
Response threshold of alarm 2
Function of alarm output
Fault + not automatic
Fault + not automatic + BI
("+" means logical OR operation)
Monitoring time for fault message
"control deviation"
Response threshold for fault message
"control deviation"
Limit for stroke integral
Limit for direction change
Limit for end stop monitoring, bottom
Limit for end stop monitoring, top
Limit for dead zone monitoring
Preset (factory setting)
"no" nothing activated
"Strt" start of factory setting after pressing key for 5 s
"oCAY" display following successful factory setting
CAUTION: preset results in "NO INIT"
4)
5)
Parameter values
turn (part-turn actuator)
WAY (linear actuator)
LWAY (linear actuator
without sine correction)
ncSt (part-turn actuator with NCS)
-ncSt (ditto, inv. direction of action)
ncSL (linear actuator with NCS)
90°
33°
OFF
OFF
5 | 10 | 15 | 20
(short lever 33°)
25 | 30 | 35
(short lever 90°)
40 | 50 | 60 | 70 | 90 | 110 | 130
(long lever 90°)
noini | no / ###.# | Strt
noini | no / ###.# | Strt
0 MA
4 MA
rising
riSE
falling
FALL
0,0 to 100,0
0,0 to 100,0
Auto
0 to 400
0 to 400
Linear
Lin
1- 25
1 - 33
1 - 50
n1 - 25
n1 - 33
n1 - 50
FrEE
0,0 to 100,0
Auto
0,1 to 10,0
0,0 to 100,0
0,0 to 100,0
MPOS
FLOW
To flow
Rising
riSE
Falling
FALL
no
Without
uP
Top only
do
uP do
0,0 to 100,0
0,0 to 100,0
None
OFF
OFF
OFF
on
-on
bLoc1
bLoc2
uP
-uP
doWn
-doWn
StoP
-StoP
None
OFF
on
-on
-uP
uP
doWn
-doWn
StoP
-StoP
OFF
0,0 to 100,0
0,0 to 100,0
on fault
Auto
0 to 100
Auto
0,0 to 100,0
OFF
1 to 1.00E9
OFF
1 to 1.00E9
OFF
0,0 to 100,0
OFF
0,0 to 100,0
OFF
0,0 to 10,0
no
Strt
oCAY
action with opened switch or Low level
NC contact means:
action with closed switch or High level
NO contact means:
Normal means:
High level without fault
Inverted means:
Low level without fault
Unit
Factory setting
Customer setting
WAY
Degrees
33°
mm
OFF
no
no
4 MA
riSE
0,0
%
100
%
0
s
0
s
Lin
0.0
5.0
%
etc. to
95.0
100.0
%
Auto
%
0,0
100,0
%
MPOS
riSE
no
%
0,5
%
99,5
OFF
OFF
OFF
%
10,0
90,0
%
s
Auto
%
Auto
OFF
OFF
%
OFF
%
OFF
%
OFF