Herunterladen Inhalt Inhalt Diese Seite drucken

Baxi Luna HT 1.850 Gebrauchsanleitung Seite 82

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

parameter
parameter description
n.
p1
Time of day setting
p5
Minimum central heating temperature setting (°C)
p11
Start of first daily period of automatic central heating
p12
End of first daily period of automatic central heating
p13
Start of second daily period of automatic central heating
p14
End of second daily period of automatic central heating
p15
Start of third daily period of automatic heating
p16
End of third daily period of automatic central heating
p31
Start of first daily period of domestic hot water production (*)
p32
End of first daily period of domestic hot water production (*)
p33
Start of second daily period of domestic hot water production (*)
p34
End of second daily period of domestic hot water production (*)
p35
Start of third daily period of domestic hot water production (*)
p36
Fine End of third daily period of domestic hot water production (*)
p45
Reset of daily central heating and domestic hot water production programs (factory
settings). Press the - + keys together for about 3 seconds; the number 1 appears on the
display. Confirm by pressing either of the
Note: Parameters from p31 to p36 can be displayed only if the domestic hot water program has been enabled
as described in chapter 15 for the attention of the installer (parameter H91).
InstructIons pertaInInG to the user
3.7 table of user-settable parameters
keys
82
Factory
range
setting
———-
0...23:59
25
25..80
6:00
00:00...24:00
22:00
00:00...24:00
0:00
00:00...24:00
0:00
00:00...24:00
0:00
00:00...24:00
0:00
00:00...24:00
0:00
00:00...24:00
24:00
00:00...24:00
0:00
00:00...24:00
0:00
00:00...24:00
0:00
00:00...24:00
0:00
00:00...24:00
0
0...1
912.198.1 - GB